Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,843

matching recommendations
Reset
ARC 2 ENERGY MANAGEMENT
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KG0081 # 01 Y:1997 01 1997 INSTALL OCCUPANCY SENSORS $1,347 $260 n/a
KG0081 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,028 $317 n/a
KG0081 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $508 $260 n/a
HO0143 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,952 $4,592 Implemented
HO0143 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $618 $1,160 Implemented
HO0143 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $679 $400 Not Implemented
HO0142 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,261 $10,505 Implemented
HO0142 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $750 $365 Not Implemented
HO0142 # 03 Y:1997 03 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,003 $800 Not Implemented
HO0142 # 04 Y:1997 04 1997 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,770 $750 Not Implemented
HO0142 # 05 Y:1997 05 1997 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $23,805 $0 Not Implemented
BD0077 # 01 Y:1997 01 1997 RECOVER WASTE HEAT FROM EQUIPMENT $13,704 $4,000 Not Implemented
BD0077 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,964 $10,588 Implemented
BD0077 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $2,534 $2,745 Not Implemented
BD0077 # 04 Y:1997 04 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,692 $6,230 Implemented
BD0077 # 05 Y:1997 05 1997 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,892 $2,500 Implemented
BD0076 # 01 Y:1997 01 1997 RECOVER WASTE HEAT FROM EQUIPMENT $11,003 $2,000 n/a
BD0076 # 02 Y:1997 02 1997 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $1,713 $2,690 n/a
BD0076 # 03 Y:1997 03 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,623 $5,410 n/a
BD0076 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,498 $500 n/a
BD0076 # 05 Y:1997 05 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,363 $0 n/a
BD0076 # 06 Y:1997 06 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $705 $1,007 n/a
BD0076 # 07 Y:1997 07 1997 INSTALL OCCUPANCY SENSORS $445 $450 n/a
KG0080 # 01 Y:1997 01 1997 INSTALL TIMERS AND/OR THERMOSTATS $6,790 $150 n/a
KG0080 # 02 Y:1997 02 1997 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $5,869 $500 n/a