Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

8,365

matching recommendations
Reset
ARC 2.1 Combustion Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0044 # 04 Y:1985 04 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $368 $300 Not Implemented
CO0046 # 03 Y:1985 03 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $16,126 $29,000 Not Implemented
CO0047 # 01 Y:1985 01 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,203 $4,000 Not Implemented
CO0049 # 08 Y:1985 08 1985 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $11,647 $20,000 Implemented
LT0049 # 03 Y:1985 03 1985 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $11,720 $10,000 Implemented
ST0047 # 09 Y:1985 09 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $617 $200 Implemented
UD0181 # 01 Y:1985 01 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,612 $200 Implemented
CO0049 # 03 Y:1985 03 1985 INSTALL TURBULATORS $1,131 $1,000 Not Implemented
CO0045 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,736 $300 Implemented
CO0048 # 05 Y:1985 05 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $128 $300 Implemented
CO0049 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,488 $300 Implemented
GT0270 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,036 $10,000 Implemented
KU0181 # 06 Y:1985 06 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $260 $0 Not Implemented
LT0043 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $901 $300 Implemented
LT0049 # 01 Y:1985 01 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,407 $0 Implemented
LT0050 # 01 Y:1985 01 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $8,567 $900 Implemented
MA0045 # 09 Y:1985 09 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $845 $1,100 Implemented
GT0274 # 03 Y:1985 03 1985 REPLACE BOILER $11,945 $32,000 Implemented
AT0032 # 02 Y:1985 02 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,391 $300 Implemented
LT0043 # 03 Y:1985 03 1985 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $1,159 $200 Implemented
LT0043 # 06 Y:1985 06 1985 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $402 $1,020 Not Implemented
KU0181 # 07 Y:1985 07 1985 INSTALL AUTOMATIC STACK DAMPER $688 $700 Not Implemented
ST0047 # 10 Y:1985 10 1985 INSTALL AUTOMATIC STACK DAMPER $819 $1,950 Not Implemented
ST0049 # 11 Y:1985 11 1985 INSTALL AUTOMATIC STACK DAMPER $961 $4,950 Not Implemented
ST0047 # 12 Y:1985 12 1985 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $5,779 $300 Not Implemented