Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

435

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0099 # 04 Y:1987 04 1987 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $1,768 $4,000 Not Implemented
CO0099 # 03 Y:1987 03 1987 HEAT WATER WITH EXHAUST HEAT $9,892 $20,200 Not Implemented
CO0099 # 02 Y:1987 02 1987 REPAIR AND ELIMINATE STEAM LEAKS $805 $900 Implemented
AM0010 # 01 Y:1987 01 1987 RECOVER WASTE HEAT FROM EQUIPMENT $1,664 $69 Not Implemented
AM0010 # 03 Y:1987 03 1987 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $1,886 $2,394 Implemented
AM0011 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $10,709 $5,600 Not Implemented
AM0011 # 05 Y:1987 05 1987 RECOVER WASTE HEAT FROM EQUIPMENT $2,870 $300 Implemented
OR0011 # 06 Y:1987 06 1987 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $4,103 $3,000 Not Implemented
OR0011 # 05 Y:1987 05 1987 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $4,969 $3,600 Not Implemented
OR0011 # 04 Y:1987 04 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $3,519 $1,536 Implemented
OR0011 # 03 Y:1987 03 1987 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,474 $0 Not Implemented
OR0011 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $389 $96 Implemented
OR0010 # 03 Y:1987 03 1987 INCREASE AMOUNT OF CONDENSATE RETURNED $31,778 $2,900 Implemented
OR0009 # 06 Y:1987 06 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $6,380 $2,300 Not Implemented
OK0234 # 07 Y:1987 07 1987 INSULATE BARE EQUIPMENT $1,006 $2,458 Implemented
AT0090 # 06 Y:1987 06 1987 INSULATE BARE EQUIPMENT $1,997 $4,900 Not Implemented
AT0091 # 04 Y:1987 04 1987 ISOLATE HOT OR COLD EQUIPMENT $484 $200 Not Implemented
RU0008 # 01 Y:1987 01 1987 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $1,791 $456 Implemented
RU0009 # 01 Y:1987 01 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $4,150 $4,392 Not Implemented
RU0009 # 05 Y:1987 05 1987 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $140 $300 Not Implemented
TN0316 # 01 Y:1987 01 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $12,770 $2,128 Implemented
TN0316 # 02 Y:1987 02 1987 USE MINIMUM STEAM OPERATING PRESSURE $612 $0 Implemented
TN0316 # 05 Y:1987 05 1987 INSULATE BARE EQUIPMENT $2,271 $4,080 Implemented
TN0316 # 07 Y:1987 07 1987 RECOVER WASTE HEAT FROM EQUIPMENT $515 $800 Implemented
TN0316 # 09 Y:1987 09 1987 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $228 $72 Implemented