Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19,994

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0002 # 04 Y:1987 04 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,563 $4,730 Not Implemented
OR0003 # 01 Y:1987 01 1987 USE MINIMUM STEAM OPERATING PRESSURE $486 $0 Implemented
OR0003 # 03 Y:1987 03 1987 INSULATE BARE EQUIPMENT $2,130 $447 Implemented
OR0003 # 05 Y:1987 05 1987 INSULATE BARE EQUIPMENT $432 $190 Implemented
OR0003 # 06 Y:1987 06 1987 INSTALL / REPAIR INSULATION ON STEAM LINES $334 $246 Implemented
OR0003 # 10 Y:1987 10 1987 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,940 $7,000 Implemented
OR0004 # 01 Y:1987 01 1987 USE MINIMUM STEAM OPERATING PRESSURE $617 $0 Not Implemented
OR0004 # 04 Y:1987 04 1987 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $98,800 $0 Implemented
OR0004 # 05 Y:1987 05 1987 HEAT WATER WITH EXHAUST HEAT $28,800 $9,000 Not Implemented
OR0004 # 06 Y:1987 06 1987 INSULATE BARE EQUIPMENT $1,008 $528 Implemented
OR0004 # 08 Y:1987 08 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,301 $4,205 Not Implemented
RU0006 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $3,147 $648 Not Implemented
RU0006 # 06 Y:1987 06 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $8,856 $9,500 Not Implemented
LT0091 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $514 $159 Implemented
MA0091 # 01 Y:1987 01 1987 RECOVER WASTE HEAT FROM EQUIPMENT $712 $100 Not Implemented
MA0091 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $4,334 $1,215 Not Implemented
MA0092 # 01 Y:1987 01 1987 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS $766 $500 Implemented
MA0092 # 04 Y:1987 04 1987 INSULATE BARE EQUIPMENT $908 $192 Not Implemented
MA0093 # 06 Y:1987 06 1987 REPAIR OR REPLACE STEAM TRAPS $940 $900 Implemented
MA0094 # 02 Y:1987 02 1987 REPAIR OR REPLACE STEAM TRAPS $1,541 $600 Implemented
TN0308 # 04 Y:1987 04 1987 INSULATE BARE EQUIPMENT $603 $1,440 Implemented
AT0073 # 04 Y:1987 04 1987 RECOVER WASTE HEAT FROM EQUIPMENT $6,666 $1,500 Implemented
AT0073 # 06 Y:1987 06 1987 INSULATE BARE EQUIPMENT $1,583 $150 Implemented
AT0074 # 01 Y:1987 01 1987 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $21,967 $6,000 Not Implemented
AT0074 # 03 Y:1987 03 1987 INSULATE BARE EQUIPMENT $6,123 $5,000 Implemented