Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

20,398

matching recommendations
Reset
ARC 2.2 Thermal Systems
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ST0075 # 04 Y:1986 04 1986 INCREASE AMOUNT OF CONDENSATE RETURNED $78,667 $20,000 Not Implemented
ST0075 # 07 Y:1986 07 1986 REPAIR OR REPLACE STEAM TRAPS $6,449 $500 Implemented
ST0076 # 02 Y:1986 02 1986 RECOVER WASTE HEAT FROM EQUIPMENT $1,121 $500 Implemented
ST0080 # 02 Y:1986 02 1986 RECOVER WASTE HEAT FROM EQUIPMENT $9,482 $7,000 Implemented
LT0059 # 02 Y:1986 02 1986 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $1,100 $4,260 Not Implemented
LT0073 # 01 Y:1986 01 1986 RECOVER WASTE HEAT FROM EQUIPMENT $1,670 $250 Not Implemented
LT0073 # 06 Y:1986 06 1986 INSULATE BARE EQUIPMENT $269 $210 Not Implemented
MA0071 # 02 Y:1986 02 1986 INSULATE BARE EQUIPMENT $13,827 $2,280 Implemented
MA0071 # 07 Y:1986 07 1986 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $2,326 $15,600 Implemented
MA0071 # 08 Y:1986 08 1986 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $3,104 $6,688 Implemented
MA0072 # 02 Y:1986 02 1986 REPAIR OR REPLACE STEAM TRAPS $13,251 $600 Implemented
UD0213 # 03 Y:1987 03 1987 USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC $45,881 $100,000 Not Implemented
UD0213 # 05 Y:1987 05 1987 RECOVER WASTE HEAT FROM EQUIPMENT $6,181 $15,000 Implemented
UD0214 # 04 Y:1987 04 1987 COVER OPEN TANKS $1,924 $400 Not Implemented
UD0215 # 03 Y:1987 03 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,008 $6,500 Not Implemented
UD0215 # 04 Y:1987 04 1987 RECOVER WASTE HEAT FROM EQUIPMENT $265 $300 Implemented
UD0207 # 03 Y:1986 03 1986 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $295 $240 Implemented
UD0209 # 02 Y:1986 02 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,078 $500 Implemented
UD0210 # 06 Y:1986 06 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,670 $10,000 Implemented
UD0210 # 07 Y:1986 07 1986 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $8,336 $18,000 Implemented
UD0210 # 08 Y:1986 08 1986 USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS $3,244 $10,000 Implemented
UD0212 # 01 Y:1987 01 1987 RECOVER WASTE HEAT FROM EQUIPMENT $2,241 $1,000 Implemented
UD0212 # 03 Y:1987 03 1987 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $34,293 $90,000 Not Implemented
GT0294 # 05 Y:1986 05 1986 USE MINIMUM SAFE OVEN VENTILATION $46,250 $10,000 Implemented