Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22,895

matching recommendations
Reset
ARC 2.7 Building and Grounds
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0300 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,256 $16,853 Implemented
MA0300 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $4,090 $3,058 Implemented
MA0300 # 05 Y:1994 05 1994 DISCONNECT BALLASTS $1,042 $67 Implemented
HO0075 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,404 $2,245 Implemented
HO0075 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $75 $205 Implemented
HO0075 # 03 Y:1994 03 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $630 $0 Implemented
AM0212 # 03 Y:1994 03 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $140 $0 Implemented
UD0428 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,373 $2,400 Implemented
UD0428 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,231 $46,256 Implemented
SD0083 # 02 Y:1994 02 1994 INSTALL TIMERS AND/OR THERMOSTATS $4,183 $320 Implemented
SD0083 # 06 Y:1994 06 1994 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $1,046 $240 Implemented
SD0083 # 08 Y:1994 08 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,678 $330 Implemented
SD0083 # 10 Y:1994 10 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $748 $385 Implemented
SD0083 # 11 Y:1994 11 1994 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $432 $125 Implemented
OK0434 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,860 $4,250 Implemented
MA0302 # 06 Y:1994 06 1994 INSTALL OCCUPANCY SENSORS $1,995 $1,466 Implemented
IA0083 # 05 Y:1994 05 1994 INSTALL OCCUPANCY SENSORS $2,573 $3,344 Implemented
IA0083 # 07 Y:1994 07 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $986 $76 Implemented
OK0440 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,930 $16,704 Implemented
OK0440 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,522 $5,878 Implemented
TN0518 # 08 Y:1994 08 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $98 $108 Implemented
KG0002 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,101 $1,382 Implemented
AS0116 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $60,465 $81,258 Implemented
AS0116 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $4,022 $2,265 Implemented
AS0116 # 07 Y:1994 07 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $45,284 $83,400 Implemented