IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

22,117

matching recommendations
Reset
ARC 2.7 Building and Grounds
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0081 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $424 $341 Implemented
OK0072 # 04 Y:1983 04 1983 INSTALL TIMERS AND/OR THERMOSTATS $18,782 $1,129 Implemented
OK0072 # 05 Y:1983 05 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,033 $824 Implemented
OK0072 # 06 Y:1983 06 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $970 $351 Implemented
OK0075 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $10,279 $1,135 Implemented
OK0083 # 01 Y:1983 01 1983 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $2,427 $3,265 Implemented
OK0083 # 02 Y:1983 02 1983 INSTALL TIMERS AND/OR THERMOSTATS $26,153 $3,160 Implemented
OK0083 # 03 Y:1983 03 1983 INSTALL TIMERS AND/OR THERMOSTATS $3,118 $1,600 Implemented
OK0083 # 04 Y:1983 04 1983 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $1,097 $200 Implemented
OK0083 # 07 Y:1983 07 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $16,433 $34,221 Implemented
OK0083 # 08 Y:1983 08 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $469 $127 Implemented
OK0070 # 06 Y:1983 06 1983 USE RADIANT HEATER FOR SPOT HEATING $3,156 $1,000 Implemented
KU0068 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,263 $6,058 Implemented
KU0068 # 02 Y:1983 02 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $12,920 $6,931 Implemented
KU0068 # 04 Y:1983 04 1983 INSTALL TIMERS AND/OR THERMOSTATS $3,656 $149 Implemented
KU0069 # 03 Y:1983 03 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $535 $810 Implemented
GT0156 # 01 Y:1983 01 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $7,784 $12,000 Implemented
GT0156 # 02 Y:1983 02 1983 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $23,650 $0 Implemented
UD0071 # 03 Y:1983 03 1983 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $2,364 $3,680 Implemented
UD0072 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,588 $581 Implemented
UD0074 # 01 Y:1983 01 1983 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,071 $698 Implemented
UD0066 # 01 Y:1982 01 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,419 $2,525 Implemented
TN0163 # 03 Y:1982 03 1982 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $500 $0 Implemented
TN0165 # 04 Y:1982 04 1982 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,920 $500 Implemented
OK0064 # 02 Y:1982 02 1982 INSTALL TIMERS AND/OR THERMOSTATS $1,830 $400 Implemented