Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,757
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0210 # 02 Y:1991 | 02 | 1991 | REDUCE VENTILATION AIR | $2,000 | $1,800 | Implemented |
CO0210 # 03 Y:1991 | 03 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $3,900 | $6,200 | Implemented |
CO0210 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,844 | $1,824 | Implemented |
CO0210 # 11 Y:1991 | 11 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,130 | $400 | Implemented |
CO0210 # 14 Y:1991 | 14 | 1991 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $460 | $1,200 | Implemented |
AS0022 # 01 Y:1991 | 01 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $27,958 | $5,100 | Implemented |
AS0022 # 02 Y:1991 | 02 | 1991 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $12,409 | $30,000 | Implemented |
AS0022 # 07 Y:1991 | 07 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,326 | $50,000 | Implemented |
AS0022 # 08 Y:1991 | 08 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $691 | $550 | Implemented |
GT0430 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $869 | $400 | Not Implemented |
GT0430 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,074 | $2,300 | Not Implemented |
AM0114 # 01 Y:1991 | 01 | 1991 | AIR CONDITION ONLY SPACE NECESSARY | $8,432 | $2,900 | Not Implemented |
AM0114 # 02 Y:1991 | 02 | 1991 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $5,900 | $13,600 | Not Implemented |
AM0114 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $635 | $205 | Not Implemented |
AM0114 # 07 Y:1991 | 07 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $88 | $15 | Not Implemented |
AM0115 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,348 | $0 | Not Implemented |
AM0115 # 03 Y:1991 | 03 | 1991 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,020 | $3,220 | Not Implemented |
AM0116 # 03 Y:1991 | 03 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,180 | $660 | Not Implemented |
AM0116 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,055 | $0 | Not Implemented |
AM0116 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28 | $12 | Not Implemented |
AM0117 # 02 Y:1991 | 02 | 1991 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $945 | $5,640 | Not Implemented |
AM0117 # 04 Y:1991 | 04 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $93 | $100 | Not Implemented |
TN0422 # 01 Y:1991 | 01 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $49,720 | $23,800 | Implemented |
TN0422 # 04 Y:1991 | 04 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $5,413 | $0 | Implemented |
TN0422 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,798 | $1,130 | Implemented |