Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47,477
matching recommendationsARC | 2.7 | Building and Grounds |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0460 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $802 | $1,695 | Implemented |
IA0460 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $282 | $200 | Implemented |
SD0431 # 01 Y:2011 | 01 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $213 | $0 | Not Implemented |
SD0431 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $89 | $98 | Not Implemented |
SD0431 # 05 Y:2011 | 05 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,310 | $10,000 | Not Implemented |
SF0392 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $533 | $1,128 | Implemented |
SF0392 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,741 | $10,656 | Implemented |
UA3011 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,307 | $26,402 | Not Implemented |
UA3011 # 02 Y:2011 | 02 | 2011 | USE PHOTOCELL CONTROLS | $575 | $225 | Implemented |
UA3011 # 10 Y:2011 | 10 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $13,650 | $9,480 | Not Implemented |
UA3011 # 11 Y:2011 | 11 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $366 | $510 | Implemented |
UA3011 # 12 Y:2011 | 12 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $843 | $50 | Implemented |
LE0311 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $40,488 | $240 | Implemented |
LE0311 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $356 | $0 | Not Implemented |
LE0311 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,691 | $5,441 | Implemented |
LE0311 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $659 | $1,875 | Implemented |
LE0311 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $458 | $0 | Implemented |
LE0311 # 08 Y:2011 | 08 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $226 | $60 | Implemented |
LE0312 # 03 Y:2011 | 03 | 2011 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $24,192 | $75,014 | Implemented |
LE0312 # 04 Y:2011 | 04 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $15,944 | $70 | Implemented |
LE0312 # 05 Y:2011 | 05 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $1,770 | $700 | Not Implemented |
LE0312 # 06 Y:2011 | 06 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $8,883 | $2,500 | Implemented |
LE0312 # 07 Y:2011 | 07 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $8,857 | $0 | Implemented |
LE0312 # 16 Y:2011 | 16 | 2011 | INSTALL OCCUPANCY SENSORS | $11,102 | $4,725 | Not Implemented |
LE0312 # 17 Y:2011 | 17 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,966 | $18,137 | Not Implemented |