Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

9,688

matching recommendations
Reset
ARC 2.72 SPACE CONDITIONING
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ST0078 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $8,261 $1,000 Not Implemented
ST0079 # 08 Y:1986 08 1986 INSTALL TIMERS AND/OR THERMOSTATS $4,642 $300 Implemented
GT0298 # 05 Y:1986 05 1986 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $196,997 $0 Implemented
KU0206 # 03 Y:1986 03 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,935 $1,500 Implemented
ST0072 # 06 Y:1986 06 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $20,785 $36,000 Implemented
ST0073 # 07 Y:1986 07 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $3,690 $9,000 Not Implemented
ST0076 # 01 Y:1986 01 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $47,801 $60,000 Implemented
ST0077 # 06 Y:1986 06 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $27,027 $30,000 Implemented
ST0079 # 05 Y:1986 05 1986 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $8,933 $15,000 Implemented
CO0070 # 07 Y:1986 07 1986 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $68 $25 Implemented
CO0070 # 01 Y:1986 01 1986 AIR CONDITION ONLY SPACE NECESSARY $6,836 $6,420 Not Implemented
ST0079 # 07 Y:1986 07 1986 AIR CONDITION ONLY SPACE NECESSARY $1,956 $0 Not Implemented
KU0206 # 02 Y:1986 02 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,313 $107 Implemented
KU0208 # 02 Y:1986 02 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,084 $100 Implemented
OK0209 # 02 Y:1986 02 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,949 $500 Implemented
OK0209 # 03 Y:1986 03 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $22,378 $14,090 Implemented
ST0065 # 08 Y:1986 08 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,912 $3,500 Not Implemented
KU0203 # 10 Y:1986 10 1986 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $115 $250 Implemented
LT0063 # 05 Y:1986 05 1986 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $551 $300 Implemented
ST0066 # 06 Y:1986 06 1986 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $18,041 $0 Implemented
GT0295 # 04 Y:1986 04 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,400 $0 Not Implemented
GT0295 # 09 Y:1986 09 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $6,440 $0 Not Implemented
KU0204 # 05 Y:1986 05 1986 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $715 $0 Implemented
KU0202 # 06 Y:1986 06 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $486 $400 Implemented
ST0068 # 07 Y:1986 07 1986 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $112,028 $82,000 Implemented