Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0110 # 02 Y:2013 | 02 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $6,320 | $260 | Implemented |
DL0109 # 01 Y:2013 | 01 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $150,360 | $266,687 | Implemented |
DL0109 # 04 Y:2013 | 04 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,276 | $250 | Implemented |
DL0109 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,350 | $40,356 | Implemented |
DL0109 # 03 Y:2013 | 03 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $15,750 | $5,800 | Implemented |
DL0108 # 07 Y:2013 | 07 | 2013 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $543 | $0 | Implemented |
DL0108 # 05 Y:2013 | 05 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $200 | Implemented |
DL0108 # 04 Y:2013 | 04 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,687 | $270 | Implemented |
DL0108 # 03 Y:2013 | 03 | 2013 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $13,367 | $0 | Implemented |
DL0108 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $39,709 | $0 | Implemented |
DL0106 # 04 Y:2013 | 04 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $102,000 | $2,375,000 | Implemented |
DL0106 # 02 Y:2013 | 02 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $28,083 | $1,516 | Implemented |
DL0106 # 01 Y:2013 | 01 | 2013 | REDUCE VENTILATION AIR | $50,820 | $2,200 | Implemented |
DL0105 # 10 Y:2013 | 10 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $154,000 | $1,000,000 | Implemented |
DL0105 # 01 Y:2013 | 01 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $76,200 | $13,500 | Implemented |
DL0105 # 04 Y:2013 | 04 | 2013 | ADD AREA LIGHTING SWITCHES | $18,950 | $1,400 | Implemented |
DL0105 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,000 | $80 | Implemented |
DL0105 # 11 Y:2013 | 11 | 2013 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $82,900 | $420,000 | Implemented |
DL0103 # 09 Y:2013 | 09 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $1,150 | $494 | Implemented |
DL0103 # 08 Y:2013 | 08 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,200 | $100 | Implemented |
DL0103 # 04 Y:2013 | 04 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $14,700 | $100 | Implemented |
DL0103 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $28,900 | $200 | Implemented |
DL0103 # 02 Y:2013 | 02 | 2013 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $25,000 | $45,000 | Implemented |
DL0102 # 02 Y:2013 | 02 | 2013 | LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION | $25,460 | $100 | Implemented |
DL0102 # 01 Y:2013 | 01 | 2013 | REDUCE VENTILATION AIR | $31,820 | $3,200 | Implemented |