Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

387

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0743 # 01 Y:2002 01 2002 USE MINIMUM STEAM OPERATING PRESSURE $1,259 $0 Implemented
GT0743 # 08 Y:2002 08 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,666 $0 Not Implemented
GT0743 # 05 Y:2002 05 2002 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $78,433 $112,650 Not Implemented
GT0733 # 05 Y:2002 05 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,965 $14,670 Not Implemented
GT0733 # 02 Y:2002 02 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $45,343 $49,000 Not Implemented
GT0733 # 01 Y:2002 01 2002 COMBINE UTILITY METERS $13,100 $1,000 Not Implemented
GT0733 # 07 Y:2002 07 2002 INSULATE BARE EQUIPMENT $316 $1,132 Not Implemented
GT0733 # 04 Y:2002 04 2002 IMPROVE COMBUSTION CONTROL CAPABILITY $22,495 $2,500 Not Implemented
GT0733 # 06 Y:2002 06 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $51,992 $57,500 Not Implemented
GT0733 # 08 Y:2002 08 2002 $2,000,000 $200,000 Not Implemented
GT0733 # 03 Y:2002 03 2002 USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION $56,762 $237,300 Not Implemented
GT0698 # 06 Y:2000 06 2000 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $59,243 $300,000 Implemented
GT0698 # 05 Y:2000 05 2000 $108,000 $160,000 Not Implemented
GT0698 # 08 Y:2000 08 2000 RECOVER WASTE HEAT FROM EQUIPMENT $29,275 $55,000 Not Implemented
GT0698 # 09 Y:2000 09 2000 FILTER AND REUSE HYDRAULIC OIL $3,712 $6,200 Not Implemented
GT0698 # 01 Y:2000 01 2000 INSULATE BARE EQUIPMENT $7,360 $3,240 Implemented
GT0698 # 03 Y:2000 03 2000 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,389 $250 Implemented
GT0698 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $422 $192 Not Implemented
GT0698 # 02 Y:2000 02 2000 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $85,596 $65,000 Not Implemented
GT0698 # 07 Y:2000 07 2000 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,235 $1,800 Implemented
GT0698 # 10 Y:2000 10 2000 AVOID COOLING OF PROCESS STREAMS OR MATERIALS THAT MUST SUBSEQUENTLY BE HEATED $18,139 $77,275 Not Implemented
GT0661 # 06 Y:1999 06 1999 REDUCE SCRAP PRODUCTION $215,560 $112,500 Implemented
GT0661 # 04 Y:1999 04 1999 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $457 $994 Not Implemented
GT0661 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,740 $750 Not Implemented
GT0661 # 05 Y:1999 05 1999 FILTER AND REUSE HYDRAULIC OIL $684 $1,000 Not Implemented