Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

210

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0221 # 08 Y:1999 08 1999 $20,642 $11,793 Implemented
IA0220 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,950 $0 Implemented
IA0220 # 02 Y:1999 02 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,697 $500 Implemented
IA0220 # 03 Y:1999 03 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,645 $50 Not Implemented
IA0220 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,597 $232 Implemented
IA0220 # 05 Y:1999 05 1999 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,802 $0 Not Implemented
IA0219 # 01 Y:1999 01 1999 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $9,876 $1,788 Not Implemented
IA0219 # 02 Y:1999 02 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,956 $195 Not Implemented
IA0219 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,239 $0 Not Implemented
IA0219 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,916 $25 Not Implemented
IA0219 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,383 $5,695 Not Implemented
IA0219 # 06 Y:1999 06 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,373 $246 Not Implemented
IA0219 # 07 Y:1999 07 1999 INSTALL OCCUPANCY SENSORS $237 $1,197 Not Implemented
IA0219 # 08 Y:1999 08 1999 MINIMIZE WATER USAGE $95,331 $50 Not Implemented
IA0219 # 09 Y:1999 09 1999 $254,475 $511,800 Not Implemented
IA0219 # 10 Y:1999 10 1999 $28,975 $132 Not Implemented
IA0218 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,310 $14,754 Not Implemented
IA0218 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,756 $20,756 Not Implemented
IA0218 # 03 Y:1999 03 1999 INSTALL OCCUPANCY SENSORS $2,081 $2,195 Not Implemented
IA0218 # 04 Y:1999 04 1999 RECOVER WASTE HEAT FROM EQUIPMENT $876 $87 Not Implemented
IA0218 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $151 $0 Not Implemented
IA0218 # 06 Y:1999 06 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $420 $272 Implemented
IA0218 # 07 Y:1999 07 1999 REDUCE / ELIMINATE USE OF DISPOSABLE PRODUCT $3,187 $2,656 Not Implemented
IA0217 # 01 Y:1999 01 1999 REPLACE BOILER $22,643 $12,000 Not Implemented
IA0217 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,292 $2,306 Implemented