Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
540
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0148 # 12 Y:1984 | 12 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,177 | $17 | Implemented |
KU0148 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,910 | $36 | Implemented |
KU0149 # 14 Y:1984 | 14 | 1984 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $834 | $1,300 | Not Implemented |
KU0149 # 12 Y:1984 | 12 | 1984 | REPAIR AND ELIMINATE STEAM LEAKS | $125 | $20 | Implemented |
KU0149 # 01 Y:1984 | 01 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $34,443 | $3,262 | Implemented |
KU0149 # 08 Y:1984 | 08 | 1984 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $1,626 | $700 | Not Implemented |
KU0149 # 19 Y:1984 | 19 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $131 | $0 | Not Implemented |
KU0148 # 08 Y:1984 | 08 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $99 | $150 | Not Implemented |
KU0149 # 24 Y:1984 | 24 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $486 | $0 | Implemented |
KU0149 # 04 Y:1984 | 04 | 1984 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,550 | $75 | Not Implemented |
KU0149 # 17 Y:1984 | 17 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $534 | $0 | Not Implemented |
KU0149 # 11 Y:1984 | 11 | 1984 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $339 | $350 | Not Implemented |
KU0148 # 14 Y:1984 | 14 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $760 | $0 | Implemented |
KU0149 # 03 Y:1984 | 03 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $965 | $400 | Implemented |
KU0149 # 13 Y:1984 | 13 | 1984 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $911 | $820 | Implemented |
KU0147 # 07 Y:1984 | 07 | 1984 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,806 | $1,900 | Not Implemented |
KU0147 # 06 Y:1984 | 06 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,700 | $7,958 | Not Implemented |
KU0147 # 02 Y:1984 | 02 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $32,837 | $12,000 | Not Implemented |
KU0147 # 04 Y:1984 | 04 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,122 | $9,277 | Not Implemented |
KU0147 # 08 Y:1984 | 08 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,520 | $1,500 | Not Implemented |
KU0147 # 05 Y:1984 | 05 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,223 | $500 | Not Implemented |
KU0147 # 10 Y:1984 | 10 | 1984 | TURN OFF EQUIPMENT WHEN NOT IN USE | $234 | $0 | Not Implemented |
KU0147 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $43,682 | $23,000 | Implemented |
KU0146 # 22 Y:1984 | 22 | 1984 | INSTALL TURBULATORS | $1,530 | $1,750 | Implemented |
KU0146 # 19 Y:1984 | 19 | 1984 | INSTALL TURBULATORS | $1,427 | $1,176 | Implemented |