Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,813
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0456 # 04 Y:1995 | 04 | 1995 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $138 | $217 | Implemented |
KU0456 # 05 Y:1995 | 05 | 1995 | INCREASE AMOUNT OF CONDENSATE RETURNED | $150 | $450 | Implemented |
KU0456 # 06 Y:1995 | 06 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,740 | $3,500 | Implemented |
KU0455 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,741 | $751 | Not Implemented |
KU0455 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,604 | $2,876 | Not Implemented |
KU0455 # 03 Y:1995 | 03 | 1995 | INSTALL OCCUPANCY SENSORS | $237 | $300 | Not Implemented |
KU0455 # 04 Y:1995 | 04 | 1995 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $830 | $2,950 | Not Implemented |
KU0455 # 05 Y:1995 | 05 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $257 | $539 | Not Implemented |
KU0455 # 06 Y:1995 | 06 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $208 | $55 | Not Implemented |
KU0455 # 07 Y:1995 | 07 | 1995 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $120 | $15 | Not Implemented |
KU0454 # 01 Y:1995 | 01 | 1995 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,987 | $18,760 | Implemented |
KU0454 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,681 | $10,200 | Implemented |
KU0454 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,625 | $8,741 | Implemented |
KU0454 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,851 | $5,940 | Not Implemented |
KU0454 # 05 Y:1995 | 05 | 1995 | INSTALL OCCUPANCY SENSORS | $2,037 | $1,750 | Not Implemented |
KU0454 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $778 | $1,140 | Implemented |
KU0454 # 07 Y:1995 | 07 | 1995 | USE PHOTOCELL CONTROLS | $548 | $120 | Implemented |
KU0454 # 08 Y:1995 | 08 | 1995 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $737 | $333 | Not Implemented |
KU0454 # 09 Y:1995 | 09 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $831 | $865 | Implemented |
KU0454 # 10 Y:1995 | 10 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $157 | $176 | Implemented |
KU0453 # 01 Y:1995 | 01 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,320 | $17,800 | Not Implemented |
KU0453 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,625 | $4,257 | Not Implemented |
KU0453 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $559 | $1,920 | Not Implemented |
KU0453 # 04 Y:1995 | 04 | 1995 | INSTALL OCCUPANCY SENSORS | $270 | $350 | Not Implemented |
KU0453 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $939 | $1,922 | Not Implemented |