Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
951
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0342 # 03 Y:2011 | 03 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,650 | $490 | Implemented |
LL0342 # 08 Y:2011 | 08 | 2011 | INSTALL OCCUPANCY SENSORS | $45 | $210 | Implemented |
LL0342 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $153 | $167 | Implemented |
LL0342 # 05 Y:2011 | 05 | 2011 | USE PHOTOCELL CONTROLS | $186 | $120 | Implemented |
LL0340 # 09 Y:2010 | 09 | 2010 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $356 | $425 | Implemented |
LL0340 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,383 | $8 | Implemented |
LL0340 # 05 Y:2010 | 05 | 2010 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $4,310 | $420 | Implemented |
LL0340 # 04 Y:2010 | 04 | 2010 | USE PHOTOCELL CONTROLS | $4,851 | $210 | Implemented |
LL0340 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,760 | $1,600 | Implemented |
LL0340 # 01 Y:2010 | 01 | 2010 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $13,551 | $1,457 | Implemented |
LL0338 # 09 Y:2010 | 09 | 2010 | USE PHOTOCELL CONTROLS | $307 | $30 | Implemented |
LL0339 # 03 Y:2010 | 03 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $152,895 | $42,400 | Implemented |
LL0339 # 02 Y:2010 | 02 | 2010 | INCREASE AMOUNT OF CONDENSATE RETURNED | $204,298 | $966,460 | Implemented |
LL0339 # 01 Y:2010 | 01 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $271,505 | $2,920 | Implemented |
LL0337 # 05 Y:2010 | 05 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,875 | $1,650 | Implemented |
LL0337 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $88,374 | $59,360 | Implemented |
LL0336 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $1,947 | $2,100 | Implemented |
LL0336 # 04 Y:2010 | 04 | 2010 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $3,008 | $630 | Implemented |
LL0336 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $26,938 | $6,840 | Implemented |
LL0335 # 08 Y:2010 | 08 | 2010 | INSULATE BARE EQUIPMENT | $313 | $123 | Implemented |
LL0335 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,558 | $4,290 | Implemented |
LL0333 # 05 Y:2010 | 05 | 2010 | INSULATE BARE EQUIPMENT | $3,966 | $5,315 | Implemented |
LL0333 # 02 Y:2010 | 02 | 2010 | REPAIR AND ELIMINATE STEAM LEAKS | $288,465 | $36,500 | Implemented |
LL0333 # 01 Y:2010 | 01 | 2010 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $2,585,020 | $273,500 | Implemented |
LL0331 # 02 Y:2010 | 02 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $13,477 | $1,200 | Implemented |