IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

936

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LM0009 # 02 Y:2001 02 2001 INSTALL SKYLIGHTS $36,728 $66,000 n/a
LM0009 # 03 Y:2001 03 2001 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $8,805 $12,000 n/a
LM0009 # 04 Y:2001 04 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $95,096 $450 n/a
LM0009 # 05 Y:2001 05 2001 $1,277,400 $300,000 n/a
LM0009 # 06 Y:2001 06 2001 $90,000 $45,696 n/a
LM0008 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,518 $500 Implemented
LM0008 # 02 Y:2001 02 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $44,725 $15,270 Not Implemented
LM0008 # 03 Y:2001 03 2001 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $787 $0 Implemented
LM0008 # 04 Y:2001 04 2001 RECOVER WASTE HEAT FROM EQUIPMENT $9,758 $1,463 Not Implemented
LM0008 # 05 Y:2001 05 2001 $36,000 $27,600 Implemented
LM0008 # 06 Y:2001 06 2001 $146,432 $17,000 Implemented
LM0008 # 07 Y:2001 07 2001 $332,648 $0 Implemented
LM0006 # 01 Y:2001 01 2001 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $14,800 $225 Not Implemented
LM0006 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,389 $450 Implemented
LM0006 # 03 Y:2001 03 2001 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,601 $0 Not Implemented
LM0006 # 04 Y:2001 04 2001 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $8,671 $13,000 Not Implemented
LM0006 # 05 Y:2001 05 2001 INSTALL SKYLIGHTS $952 $2,000 Not Implemented
LM0006 # 06 Y:2001 06 2001 $11,340 $1,000 Not Implemented
LM0006 # 07 Y:2001 07 2001 $48,228 $25,000 Implemented
LM0006 # 08 Y:2001 08 2001 $9,168 $1,961 Not Implemented
LM0007 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,501 $630 Implemented
LM0007 # 02 Y:2001 02 2001 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY $2,859 $500 Not Implemented
LM0007 # 03 Y:2001 03 2001 INSTALL SKYLIGHTS $1,567 $3,000 Implemented
LM0007 # 04 Y:2001 04 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,741 $12,000 Not Implemented
LM0007 # 05 Y:2001 05 2001 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $26,071 $150 Implemented