IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,692

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0343 # 04 Y:1995 04 1995 ELIMINATE COMBUSTIBLE GAS IN FLUE GAS $2,131 $1,750 Not Implemented
MA0343 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,114 $6,330 Implemented
MA0343 # 06 Y:1995 06 1995 COVER OPEN TANKS $828 $274 Implemented
MA0340 # 01 Y:1995 01 1995 USE POWER DURING OFF-PEAK PERIODS $4,800 $0 Implemented
MA0340 # 02 Y:1995 02 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,349 $200 Implemented
MA0340 # 03 Y:1995 03 1995 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,634 $5,995 Not Implemented
MA0340 # 04 Y:1995 04 1995 PAY UTILITY BILLS ON TIME $1,820 $0 Implemented
MA0340 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,369 $2,464 Implemented
MA0340 # 06 Y:1995 06 1995 REDUCE VENTILATION AIR $1,190 $3,320 Implemented
MA0340 # 07 Y:1995 07 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $753 $0 Implemented
MA0340 # 08 Y:1995 08 1995 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $612 $330 Implemented
MA0340 # 09 Y:1995 09 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $558 $127 Not Implemented
MA0340 # 10 Y:1995 10 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $356 $570 Implemented
MA0339 # 01 Y:1995 01 1995 BURN A LESS EXPENSIVE GRADE OF FUEL $4,128 $1,860 Implemented
MA0339 # 02 Y:1995 02 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $1,027 $3,770 Implemented
MA0339 # 03 Y:1995 03 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $653 $0 Implemented
MA0339 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $504 $1,010 Not Implemented
MA0339 # 05 Y:1995 05 1995 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $57,939 $118,450 Not Implemented
MA0339 # 06 Y:1995 06 1995 RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER $23,990 $500 Not Implemented
MA0339 # 07 Y:1995 07 1995 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $824 $3,000 Not Implemented
MA0341 # 01 Y:1995 01 1995 PAY UTILITY BILLS ON TIME $1,707 $0 Implemented
MA0341 # 02 Y:1995 02 1995 INSTALL OCCUPANCY SENSORS $1,207 $1,440 Not Implemented
MA0341 # 03 Y:1995 03 1995 COMBINE UTILITY METERS $1,091 $200 Not Implemented
MA0341 # 04 Y:1995 04 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $721 $0 Not Implemented
MA0341 # 05 Y:1995 05 1995 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $511 $711 Not Implemented