Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,929

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0369 # 04 Y:1996 04 1996 USE MAGNETIC TECHNOLOGY TO TREAT WATER $2,500 $850 Not Implemented
MA0369 # 05 Y:1996 05 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,541 $3,401 Not Implemented
MA0369 # 06 Y:1996 06 1996 USE DEMAND CONTROLLER OR LOAD SHEDDER $919 $0 Implemented
MA0374 # 01 Y:1996 01 1996 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $5,688 $2,183 Implemented
MA0374 # 02 Y:1996 02 1996 INSTALL TIMERS AND/OR THERMOSTATS $3,185 $1,720 Implemented
MA0374 # 03 Y:1996 03 1996 USE MAGNETIC TECHNOLOGY TO TREAT WATER $1,575 $11,399 Not Implemented
MA0374 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $352 $130 Not Implemented
MA0373 # 01 Y:1996 01 1996 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $12,250 $3,800 Not Implemented
MA0373 # 02 Y:1996 02 1996 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $4,884 $705 Not Implemented
MA0373 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,081 $9,888 Not Implemented
MA0373 # 04 Y:1996 04 1996 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $843 $448 Implemented
MA0373 # 05 Y:1996 05 1996 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $587 $2,000 Not Implemented
MA0366 # 01 Y:1996 01 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,638 $0 Not Implemented
MA0366 # 02 Y:1996 02 1996 OPTIMIZE PLANT POWER FACTOR $11,369 $9,450 Implemented
MA0366 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,893 $20,255 Not Implemented
MA0366 # 04 Y:1996 04 1996 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,919 $9,000 Not Implemented
MA0366 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,474 $350 Implemented
MA0366 # 06 Y:1996 06 1996 RECOVER AND REUSE COOLING WATER $1,421 $1,471 Not Implemented
MA0366 # 07 Y:1996 07 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,093 $4,910 Not Implemented
MA0366 # 08 Y:1996 08 1996 UTILIZE A LESS EXPENSIVE COOLING METHOD $435 $250 Not Implemented
MA0368 # 01 Y:1996 01 1996 TREAT AND REUSE RINSE WATERS $17,190 $12,000 Not Implemented
MA0368 # 02 Y:1996 02 1996 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $8,710 $25,500 Not Implemented
MA0368 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,509 $11,189 Implemented
MA0368 # 04 Y:1996 04 1996 REPAIR OR REPLACE STEAM TRAPS $1,990 $868 Implemented
MA0368 # 05 Y:1996 05 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,042 $2,804 Not Implemented