Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,692
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0538 # 05 Y:2003 | 05 | 2003 | COVER OPEN TANKS | $12,160 | $39,000 | Not Implemented |
MA0538 # 06 Y:2003 | 06 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $10,594 | $44,750 | Not Implemented |
MA0538 # 07 Y:2003 | 07 | 2003 | OPTIMIZE PLANT POWER FACTOR | $10,424 | $31,667 | Not Implemented |
MA0538 # 08 Y:2003 | 08 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,238 | $85 | Implemented |
MA0537 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $94,545 | $112,240 | Not Implemented |
MA0537 # 02 Y:2003 | 02 | 2003 | ADOPT IN-HOUSE MATERIAL GENERATION | $61,752 | $240,000 | Not Implemented |
MA0537 # 03 Y:2003 | 03 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,180 | $8,000 | Not Implemented |
MA0537 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,446 | $10,396 | Implemented |
MA0537 # 05 Y:2003 | 05 | 2003 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,043 | $3,500 | Not Implemented |
MA0537 # 06 Y:2003 | 06 | 2003 | INSTALL OCCUPANCY SENSORS | $464 | $150 | Implemented |
MA0537 # 07 Y:2003 | 07 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $154 | $0 | Implemented |
MA0536 # 01 Y:2003 | 01 | 2003 | RECOVER WASTE HEAT FROM EQUIPMENT | $112,689 | $118,000 | Implemented |
MA0536 # 02 Y:2003 | 02 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $91,341 | $30,000 | Implemented |
MA0536 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $64,338 | $60,000 | Implemented |
MA0536 # 04 Y:2003 | 04 | 2003 | USE STEAM CONDENSATE FOR HOT WATER SUPPLY (NON-POTABLE) | $69,333 | $5,900 | Implemented |
MA0536 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $20,935 | $22,000 | n/a |
MA0536 # 06 Y:2003 | 06 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,568 | $8,480 | Not Implemented |
MA0536 # 07 Y:2003 | 07 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,205 | $11,500 | n/a |
MA0536 # 08 Y:2003 | 08 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,766 | $11,500 | n/a |
MA0536 # 09 Y:2003 | 09 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,484 | $11,500 | n/a |
MA0536 # 10 Y:2003 | 10 | 2003 | INSULATE BARE EQUIPMENT | $5,400 | $2,600 | Implemented |
MA0536 # 11 Y:2003 | 11 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,456 | $8,000 | n/a |
MA0536 # 12 Y:2003 | 12 | 2003 | INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE | $3,444 | $2,250 | Not Implemented |
MA0536 # 13 Y:2003 | 13 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,072 | $7,350 | Not Implemented |
MA0534 # 01 Y:2003 | 01 | 2003 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $223,213 | $1,257,060 | Not Implemented |