Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,498
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0122 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $1,570 | $4,500 | Not Implemented |
ME0122 # 02 Y:1994 | 02 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $446 | $450 | Not Implemented |
ME0122 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,124 | $800 | Implemented |
ME0122 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,005 | $14,689 | Not Implemented |
ME0122 # 05 Y:1994 | 05 | 1994 | PAY UTILITY BILLS ON TIME | $1,979 | $0 | Not Implemented |
ME0124 # 01 Y:1994 | 01 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,318 | $2,800 | Not Implemented |
ME0124 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $4,574 | $9,200 | Not Implemented |
ME0124 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,730 | $200 | Not Implemented |
ME0124 # 04 Y:1994 | 04 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,717 | $4,300 | Not Implemented |
ME0124 # 05 Y:1994 | 05 | 1994 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $54,000 | $110,000 | Not Implemented |
ME0124 # 06 Y:1994 | 06 | 1994 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $16,980 | $18,000 | Not Implemented |
ME0124 # 07 Y:1994 | 07 | 1994 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $16,767 | $9,000 | Not Implemented |
ME0118 # 01 Y:1994 | 01 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,126 | $1,500 | Implemented |
ME0118 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $320 | $800 | Not Implemented |
ME0118 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $418 | $100 | Implemented |
ME0118 # 04 Y:1994 | 04 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $226 | $500 | Implemented |
ME0118 # 05 Y:1994 | 05 | 1994 | USE PHOTOCELL CONTROLS | $971 | $1,000 | Not Implemented |
ME0118 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $433 | $150 | Not Implemented |
ME0118 # 07 Y:1994 | 07 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $549 | $1,050 | Not Implemented |
ME0119 # 01 Y:1994 | 01 | 1994 | MINIMIZE WATER USAGE | $21,700 | $12,150 | Implemented |
ME0119 # 02 Y:1994 | 02 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $403 | $600 | Not Implemented |
ME0119 # 03 Y:1994 | 03 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,555 | $100 | Not Implemented |
ME0119 # 04 Y:1994 | 04 | 1994 | OPTIMIZE PLANT POWER FACTOR | $1,327 | $2,280 | Not Implemented |
ME0119 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,504 | $4,415 | Not Implemented |
ME0115 # 01 Y:1993 | 01 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $1,628 | $800 | Not Implemented |