IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,692

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
ME0127 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,963 $400 Implemented
ME0127 # 05 Y:1994 05 1994 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $565 $225 Not Implemented
ME0123 # 01 Y:1994 01 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,352 $500 Implemented
ME0123 # 02 Y:1994 02 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,038 $1,500 Implemented
ME0123 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $722 $500 Not Implemented
ME0123 # 04 Y:1994 04 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $816 $750 Not Implemented
ME0123 # 05 Y:1994 05 1994 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $21,216 $52,000 Not Implemented
ME0110 # 01 Y:1994 01 1994 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $787 $1,250 Not Implemented
ME0110 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $368 $400 Implemented
ME0110 # 03 Y:1994 03 1994 KEEP BOILER TUBES CLEAN $357 $200 Implemented
ME0121 # 01 Y:1994 01 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,078 $1,200 Not Implemented
ME0121 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,100 $400 Implemented
ME0121 # 03 Y:1994 03 1994 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $302 $150 Not Implemented
ME0121 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $552 $200 Not Implemented
ME0113 # 01 Y:1994 01 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $599 $471 Implemented
ME0113 # 02 Y:1994 02 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $845 $1,000 Implemented
ME0113 # 03 Y:1994 03 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,592 $3,500 Implemented
ME0113 # 04 Y:1994 04 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $412 $950 Implemented
ME0113 # 05 Y:1994 05 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $334 $400 Implemented
ME0122 # 01 Y:1994 01 1994 OPTIMIZE PLANT POWER FACTOR $1,570 $4,500 Not Implemented
ME0122 # 02 Y:1994 02 1994 DIRECT WARMEST AIR TO COMBUSTION INTAKE $446 $450 Not Implemented
ME0122 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,124 $800 Implemented
ME0122 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,005 $14,689 Not Implemented
ME0122 # 05 Y:1994 05 1994 PAY UTILITY BILLS ON TIME $1,979 $0 Not Implemented
ME0124 # 01 Y:1994 01 1994 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,318 $2,800 Not Implemented