Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
186
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0096 # 07 Y:2004 | 07 | 2004 | COVER OPEN TANKS | $34 | $25 | Implemented |
MI0096 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $110 | $56 | Implemented |
MI0096 # 05 Y:2004 | 05 | 2004 | USE SYNTHETIC LUBRICANT | $696 | $189 | Not Implemented |
MI0096 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $-147 | $1,015 | Not Implemented |
MI0096 # 03 Y:2004 | 03 | 2004 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,619 | $150 | Implemented |
MI0096 # 02 Y:2004 | 02 | 2004 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $3,213 | $1,250 | Implemented |
MI0096 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,113 | $800 | Not Implemented |
MI0095 # 08 Y:2004 | 08 | 2004 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $458 | $186 | Implemented |
MI0095 # 07 Y:2004 | 07 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,514 | $894 | Not Implemented |
MI0095 # 06 Y:2004 | 06 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,100 | $144 | Implemented |
MI0095 # 05 Y:2004 | 05 | 2004 | INSULATE BARE EQUIPMENT | $862 | $543 | Not Implemented |
MI0095 # 04 Y:2004 | 04 | 2004 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $2,100 | $5,660 | Not Implemented |
MI0095 # 03 Y:2004 | 03 | 2004 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $120,575 | $0 | Not Implemented |
MI0095 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $70,081 | $2,300 | Not Implemented |
MI0095 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,778 | $600 | Not Implemented |
MI0070 # 02 Y:2004 | 02 | 2004 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $197,433 | $74,805 | Implemented |
MI0070 # 01 Y:2004 | 01 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $21,868 | $2,300 | Implemented |
MI0070 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,027 | $0 | Not Implemented |
MI0070 # 04 Y:2004 | 04 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $11,397 | $5,248 | Implemented |
MI0070 # 03 Y:2004 | 03 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $175 | $0 | Not Implemented |
MI0094 # 02 Y:2004 | 02 | 2004 | REDUCE DEFECTS BY REDUCING PRODUCT TIPPING | $95,473 | $150 | Implemented |
MI0094 # 04 Y:2004 | 04 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $9,418 | $92 | Implemented |
MI0094 # 03 Y:2004 | 03 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $-177 | $590 | Implemented |
MI0094 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $24,368 | $2,300 | Implemented |
MI0094 # 05 Y:2004 | 05 | 2004 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,547 | $0 | Not Implemented |