IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,391

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0241 # 03 Y:2002 03 2002 DEVELOP A REPAIR/REPLACE POLICY $4,751 $6,493 Implemented
NC0241 # 05 Y:2002 05 2002 KEEP BOILER TUBES CLEAN $499 $1,600 Implemented
NC0237 # 01 Y:2002 01 2002 RECYCLE WHITE WATER $6,970 $3,500 Implemented
NC0237 # 02 Y:2002 02 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,443 $680 Implemented
NC0238 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN WATER LINES AND VALVES $1,890 $2,100 Implemented
NC0238 # 02 Y:2002 02 2002 REPAIR AND ELIMINATE STEAM LEAKS $3,389 $5,000 Implemented
NC0238 # 06 Y:2002 06 2002 REPAIR OR REPLACE STEAM TRAPS $10,000 $9,340 Implemented
NC0238 # 07 Y:2002 07 2002 INSTALL / REPAIR INSULATION ON STEAM LINES $1,112 $2,405 Implemented
NC0238 # 10 Y:2002 10 2002 INCREASE AMOUNT OF CONDENSATE RETURNED $4,818 $6,000 Implemented
NC0238 # 11 Y:2002 11 2002 DEVELOP A REPAIR/REPLACE POLICY $6,185 $17,736 Implemented
NC0238 # 12 Y:2002 12 2002 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM $4,536 $1,500 Implemented
NC0238 # 13 Y:2002 13 2002 RECOVER WASTE HEAT FROM EQUIPMENT $93,319 $15,000 Implemented
NC0236 # 02 Y:2002 02 2002 DEVELOP A REPAIR/REPLACE POLICY $4,419 $8,200 Implemented
NC0236 # 04 Y:2002 04 2002 USE PHOTOCELL CONTROLS $115 $260 Implemented
NC0240 # 01 Y:2002 01 2002 KEEP BOILER TUBES CLEAN $12,204 $10,000 Implemented
NC0240 # 02 Y:2002 02 2002 DEVELOP A REPAIR/REPLACE POLICY $673 $1,146 Implemented
NC0240 # 03 Y:2002 03 2002 USE PHOTOCELL CONTROLS $118 $200 Implemented
NC0240 # 04 Y:2002 04 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $132 $60 Implemented
NC0240 # 05 Y:2002 05 2002 CHECK FOR ACCURACY OF UTILITY / POWER METERS $3,000 $1,000 Implemented
NC0240 # 06 Y:2002 06 2002 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM $100,000 $200,000 Implemented
NC0239 # 02 Y:2002 02 2002 DEVELOP A REPAIR/REPLACE POLICY $614 $3,190 Implemented
NC0239 # 03 Y:2002 03 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $132 $60 Implemented
NC0235 # 01 Y:2002 01 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $17,277 $100 Implemented
NC0235 # 04 Y:2002 04 2002 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $30,410 $1,000 Implemented
NC0235 # 05 Y:2002 05 2002 DEVELOP A REPAIR/REPLACE POLICY $23,267 $15,570 Implemented