Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,985
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0161 # 01 Y:1999 | 01 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,160 | $500 | Not Implemented |
NC0161 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,328 | $20 | Not Implemented |
NC0161 # 03 Y:1999 | 03 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $6,140 | $1,650 | Implemented |
NC0161 # 04 Y:1999 | 04 | 1999 | BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT | $160,533 | $279,000 | Not Implemented |
NC0161 # 05 Y:1999 | 05 | 1999 | BURN WASTE PAPER FOR HEAT | $281 | $0 | Not Implemented |
NC0163 # 01 Y:1999 | 01 | 1999 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,222 | $17,000 | Implemented |
NC0163 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,614 | $1,600 | Implemented |
NC0163 # 03 Y:1999 | 03 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,866 | $25 | Implemented |
NC0163 # 04 Y:1999 | 04 | 1999 | COVER OPEN TANKS | $24,515 | $21,000 | Not Implemented |
NC0163 # 05 Y:1999 | 05 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $19,985 | $35,000 | Not Implemented |
NC0163 # 06 Y:1999 | 06 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,068 | $1,000 | Implemented |
NC0163 # 07 Y:1999 | 07 | 1999 | TREAT AND REUSE RINSE WATERS | $7,389 | $4,500 | Implemented |
NC0163 # 08 Y:1999 | 08 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $55,000 | $14,000 | Implemented |
NC0162 # 01 Y:1999 | 01 | 1999 | IMPROVE COMBUSTION CONTROL CAPABILITY | $9,405 | $15,000 | Not Implemented |
NC0162 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,501 | $20,000 | Not Implemented |
NC0162 # 03 Y:1999 | 03 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $41,911 | $10,500 | Not Implemented |
NC0162 # 04 Y:1999 | 04 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $7,571 | $9,450 | Not Implemented |
NC0162 # 05 Y:1999 | 05 | 1999 | METER WASTE WATER | $2,279 | $1,500 | Not Implemented |
NC0162 # 06 Y:1999 | 06 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,019 | $1,050 | Not Implemented |
NC0162 # 07 Y:1999 | 07 | 1999 | IMPROVE HANDLING PRACTICES | $1,609 | $1,500 | Not Implemented |
NC0162 # 08 Y:1999 | 08 | 1999 | MOVE PRODUCT USING MECHANICAL MEANS | $1,509 | $5,200 | Not Implemented |
NC0159 # 01 Y:1999 | 01 | 1999 | DISCONNECT BALLASTS | $5,744 | $100 | Implemented |
NC0159 # 02 Y:1999 | 02 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,313 | $600 | Implemented |
NC0159 # 03 Y:1999 | 03 | 1999 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $13,403 | $0 | Not Implemented |
NC0159 # 04 Y:1999 | 04 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,446 | $1,700 | Not Implemented |