Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,985
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0079 # 04 Y:1996 | 04 | 1996 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,117 | $3,000 | Not Implemented |
NC0079 # 05 Y:1996 | 05 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,234 | $6,000 | Not Implemented |
NC0079 # 06 Y:1996 | 06 | 1996 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $13,641 | $6,000 | Not Implemented |
NC0079 # 07 Y:1996 | 07 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,705 | $2,500 | Not Implemented |
NC0079 # 08 Y:1996 | 08 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,851 | $200 | Not Implemented |
NC0081 # 01 Y:1996 | 01 | 1996 | DISCONNECT BALLASTS | $800 | $2,060 | Implemented |
NC0081 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,438 | $17,250 | Implemented |
NC0081 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,043 | $53,739 | Implemented |
NC0081 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $558 | $480 | Implemented |
NC0081 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,626 | $2,640 | Implemented |
NC0081 # 06 Y:1996 | 06 | 1996 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $9,258 | $25,000 | Implemented |
NC0081 # 07 Y:1996 | 07 | 1996 | AIR CONDITION ONLY SPACE NECESSARY | $968 | $1,500 | Not Implemented |
NC0081 # 08 Y:1996 | 08 | 1996 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,816 | $0 | Not Implemented |
NC0081 # 09 Y:1996 | 09 | 1996 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $9,000 | $8,000 | Not Implemented |
NC0081 # 10 Y:1996 | 10 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,170 | $25,000 | Not Implemented |
NC0085 # 01 Y:1996 | 01 | 1996 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $144 | $0 | Not Implemented |
NC0085 # 02 Y:1996 | 02 | 1996 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $14,587 | $25,400 | Not Implemented |
NC0085 # 03 Y:1996 | 03 | 1996 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $738 | $600 | Implemented |
NC0085 # 04 Y:1996 | 04 | 1996 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $594 | $0 | Not Implemented |
NC0085 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $910 | $520 | Implemented |
NC0085 # 06 Y:1996 | 06 | 1996 | USE PHOTOCELL CONTROLS | $1,271 | $0 | Not Implemented |
NC0085 # 07 Y:1996 | 07 | 1996 | USE LESS WASTEFUL PACKAGING | $437 | $0 | Implemented |
NC0086 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $69 | $112 | Implemented |
NC0086 # 02 Y:1996 | 02 | 1996 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $541 | $0 | Implemented |
NC0086 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $495 | $900 | Implemented |