IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,176

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0164 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $4,553 $9,000 Implemented
NC0164 # 05 Y:1999 05 1999 MINIMIZE WATER USAGE $1,767 $0 Implemented
NC0164 # 06 Y:1999 06 1999 BURN WASTE OIL FOR HEAT $40,650 $30,000 Implemented
NC0164 # 07 Y:1999 07 1999 ADOPT IN-HOUSE MATERIAL GENERATION $1,975 $2,500 Implemented
NC0161 # 05 Y:1999 05 1999 BURN WASTE PAPER FOR HEAT $281 $0 Not Implemented
NC0161 # 01 Y:1999 01 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,160 $500 Not Implemented
NC0161 # 02 Y:1999 02 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,328 $20 Not Implemented
NC0161 # 03 Y:1999 03 1999 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,140 $1,650 Implemented
NC0161 # 04 Y:1999 04 1999 BURN WASTE TO PRODUCE STEAM TO DRIVE A STEAM TURBINE GENERATOR SET AND USE STEAM EXHAUST FOR HEAT $160,533 $279,000 Not Implemented
NC0163 # 01 Y:1999 01 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $11,222 $17,000 Implemented
NC0163 # 02 Y:1999 02 1999 RECOVER WASTE HEAT FROM EQUIPMENT $1,614 $1,600 Implemented
NC0163 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $7,866 $25 Implemented
NC0163 # 04 Y:1999 04 1999 COVER OPEN TANKS $24,515 $21,000 Not Implemented
NC0163 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $19,985 $35,000 Not Implemented
NC0163 # 06 Y:1999 06 1999 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $4,068 $1,000 Implemented
NC0163 # 07 Y:1999 07 1999 TREAT AND REUSE RINSE WATERS $7,389 $4,500 Implemented
NC0163 # 08 Y:1999 08 1999 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $55,000 $14,000 Implemented
NC0162 # 01 Y:1999 01 1999 IMPROVE COMBUSTION CONTROL CAPABILITY $9,405 $15,000 Not Implemented
NC0162 # 02 Y:1999 02 1999 RECOVER WASTE HEAT FROM EQUIPMENT $5,501 $20,000 Not Implemented
NC0162 # 03 Y:1999 03 1999 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $41,911 $10,500 Not Implemented
NC0162 # 04 Y:1999 04 1999 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $7,571 $9,450 Not Implemented
NC0162 # 05 Y:1999 05 1999 METER WASTE WATER $2,279 $1,500 Not Implemented
NC0162 # 06 Y:1999 06 1999 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $1,019 $1,050 Not Implemented
NC0162 # 07 Y:1999 07 1999 IMPROVE HANDLING PRACTICES $1,609 $1,500 Not Implemented
NC0162 # 08 Y:1999 08 1999 MOVE PRODUCT USING MECHANICAL MEANS $1,509 $5,200 Not Implemented