Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,176
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0153 # 03 Y:1998 | 03 | 1998 | ADD AREA LIGHTING SWITCHES | $91 | $300 | Not Implemented |
NC0153 # 04 Y:1998 | 04 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,508 | $500 | Not Implemented |
NC0153 # 05 Y:1998 | 05 | 1998 | INSTALL SKYLIGHTS | $10,344 | $36,000 | Not Implemented |
NC0153 # 06 Y:1998 | 06 | 1998 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $3,423 | $3,000 | Not Implemented |
NC0153 # 07 Y:1998 | 07 | 1998 | CLEAR AND RENT EXISTING SPACE | $28,000 | $20,500 | Not Implemented |
NC0152 # 01 Y:1998 | 01 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,388 | $1,000 | Not Implemented |
NC0152 # 02 Y:1998 | 02 | 1998 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,988 | $13,000 | Not Implemented |
NC0152 # 03 Y:1998 | 03 | 1998 | COVER OPEN TANKS | $1,006 | $100 | Implemented |
NC0152 # 04 Y:1998 | 04 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $396 | $80 | Not Implemented |
NC0152 # 05 Y:1998 | 05 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $3,160 | $0 | Implemented |
NC0152 # 06 Y:1998 | 06 | 1998 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $3,010 | $5,000 | Not Implemented |
NC0152 # 07 Y:1998 | 07 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $563 | $200 | Implemented |
NC0152 # 08 Y:1998 | 08 | 1998 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $16,777 | $4,000 | Not Implemented |
NC0152 # 09 Y:1998 | 09 | 1998 | EXPAND OPERATIONS INTO UNUSED SPACE | $31,250 | $12,850 | Not Implemented |
NC0154 # 01 Y:1998 | 01 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,913 | $15,000 | n/a |
NC0154 # 02 Y:1998 | 02 | 1998 | CLOSE OFF UNNEEDED STEAM LINES | $2,893 | $3,000 | n/a |
NC0154 # 03 Y:1998 | 03 | 1998 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,295 | $825 | n/a |
NC0154 # 04 Y:1998 | 04 | 1998 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,693 | $5,000 | n/a |
NC0154 # 05 Y:1998 | 05 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,140 | $0 | n/a |
NC0154 # 06 Y:1998 | 06 | 1998 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,876 | $1,500 | n/a |
NC0154 # 07 Y:1998 | 07 | 1998 | USE ADSORPTION, ION EXCHANGE TO REMOVE CONTAMINANTS | $62,900 | $5,500 | n/a |
NC0154 # 08 Y:1998 | 08 | 1998 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $520,000 | $0 | n/a |
NC0141 # 01 Y:1998 | 01 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $556 | $60 | Implemented |
NC0141 # 02 Y:1998 | 02 | 1998 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $5,943 | $10,000 | Implemented |
NC0141 # 03 Y:1998 | 03 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,183 | $4,236 | Implemented |