Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
598
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0327 # 01 Y:1999 | 01 | 1999 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $17,546 | $25,000 | Implemented |
ND0327 # 04 Y:1999 | 04 | 1999 | INSULATE BARE EQUIPMENT | $744 | $1,392 | Implemented |
ND0327 # 09 Y:1999 | 09 | 1999 | $16,882 | $0 | Implemented | |
ND0327 # 10 Y:1999 | 10 | 1999 | $1,106 | $0 | Implemented | |
ND0324 # 02 Y:1999 | 02 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,051 | $250 | Implemented |
ND0324 # 03 Y:1999 | 03 | 1999 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,258 | $30,000 | Implemented |
ND0324 # 07 Y:1999 | 07 | 1999 | REDUCE SCRAP PRODUCTION | $11,250 | $7,200 | Implemented |
ND0323 # 02 Y:1999 | 02 | 1999 | $3,731 | $250 | Implemented | |
ND0323 # 03 Y:1999 | 03 | 1999 | $2,584 | $0 | Implemented | |
ND0323 # 04 Y:1999 | 04 | 1999 | $546 | $991 | Implemented | |
ND0323 # 07 Y:1999 | 07 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $670 | $140 | Implemented |
ND0323 # 08 Y:1999 | 08 | 1999 | INSTALL OCCUPANCY SENSORS | $256 | $600 | Implemented |
ND0323 # 11 Y:1999 | 11 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $106 | $200 | Implemented |
ND0323 # 12 Y:1999 | 12 | 1999 | USE OPTIMUM TEMPERATURE | $32 | $10 | Implemented |
ND0319 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $63 | $65 | Implemented |
ND0319 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $411 | $30 | Implemented |
ND0319 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $155 | $40 | Implemented |
ND0319 # 07 Y:1999 | 07 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $283 | $510 | Implemented |
ND0317 # 03 Y:1999 | 03 | 1999 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $273 | $60 | Implemented |
ND0317 # 05 Y:1999 | 05 | 1999 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,479 | $7,733 | Implemented |
ND0317 # 06 Y:1999 | 06 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,285 | $260 | Implemented |
ND0317 # 08 Y:1999 | 08 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $146 | $70 | Implemented |
ND0310 # 01 Y:1998 | 01 | 1998 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $9,419 | $24,900 | Implemented |
ND0310 # 02 Y:1998 | 02 | 1998 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $27,164 | $9,600 | Implemented |
ND0310 # 03 Y:1998 | 03 | 1998 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $56,650 | $65,000 | Implemented |