Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,103
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0229 # 03 Y:1999 | 03 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,665 | $500 | Implemented |
SD0229 # 04 Y:1999 | 04 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,377 | $120 | Implemented |
SD0229 # 05 Y:1999 | 05 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,502 | $11,000 | Not Implemented |
SD0229 # 06 Y:1999 | 06 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,372 | $540 | Not Implemented |
SD0229 # 07 Y:1999 | 07 | 1999 | INSTALL BACK-UP EQUIPMENT | $23,040 | $15,000 | Not Implemented |
SD0229 # 08 Y:1999 | 08 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $76,320 | $30,000 | Not Implemented |
SD0230 # 01 Y:1999 | 01 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,090 | $4,048 | Implemented |
SD0230 # 02 Y:1999 | 02 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,483 | $6,030 | Not Implemented |
SD0230 # 03 Y:1999 | 03 | 1999 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $257,414 | $480,000 | Not Implemented |
SD0230 # 04 Y:1999 | 04 | 1999 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $1,099,432 | $1,975,633 | Not Implemented |
SD0230 # 05 Y:1999 | 05 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $83,680 | $0 | Implemented |
SD0230 # 06 Y:1999 | 06 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $39,860 | $16,000 | Not Implemented |
SD0230 # 07 Y:1999 | 07 | 1999 | ELIMINATE PRACTICE OF MIXING WASTE STREAMS | $27,200 | $0 | Implemented |
SD0230 # 08 Y:1999 | 08 | 1999 | PURCHASE EQUIPMENT INSTEAD OF LEASING | $0 | $2,410 | Implemented |
SD0235 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,382 | $7,776 | Not Implemented |
SD0235 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,361 | $1,782 | Not Implemented |
SD0235 # 03 Y:1999 | 03 | 1999 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $3,356 | $0 | Not Implemented |
SD0235 # 04 Y:1999 | 04 | 1999 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $18,218 | $23,830 | Implemented |
SD0235 # 05 Y:1999 | 05 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $5,852 | $0 | Not Implemented |
SD0235 # 06 Y:1999 | 06 | 1999 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $3,794 | $14,000 | Not Implemented |
SD0235 # 07 Y:1999 | 07 | 1999 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $7,690 | $0 | Not Implemented |
SD0235 # 08 Y:1999 | 08 | 1999 | IMPROVED MATERIAL HANDLING (MIXING AND TRANSFER) | $594 | $0 | Not Implemented |
SD0235 # 09 Y:1999 | 09 | 1999 | RECYCLE CLEANING SOLVENT AND REUSE | $34,580 | $20,000 | Not Implemented |
SD0235 # 10 Y:1999 | 10 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $107,143 | $115,000 | Not Implemented |
SD0235 # 11 Y:1999 | 11 | 1999 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $21,793 | $0 | Implemented |