Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,065
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0364 # 04 Y:2005 | 04 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,016 | $440 | Implemented |
SD0364 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $413 | $400 | Not Implemented |
SD0363 # 01 Y:2005 | 01 | 2005 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,477 | $17,705 | Not Implemented |
SD0363 # 02 Y:2005 | 02 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,125 | $9,250 | Not Implemented |
SD0363 # 03 Y:2005 | 03 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $5,335 | $12,575 | Not Implemented |
SD0363 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $4,442 | $8,400 | Not Implemented |
SD0363 # 05 Y:2005 | 05 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,107 | $4,600 | Not Implemented |
SD0363 # 06 Y:2005 | 06 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,580 | $640 | Not Implemented |
SD0363 # 07 Y:2005 | 07 | 2005 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,445 | $230 | Not Implemented |
SD0363 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $26,090 | $31,655 | Implemented |
SD0363 # 09 Y:2005 | 09 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $229,203 | $92,000 | Not Implemented |
SD0363 # 10 Y:2005 | 10 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $10,056 | $18,500 | Not Implemented |
SD0362 # 01 Y:2005 | 01 | 2005 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $41,074 | $6,300 | Implemented |
SD0362 # 02 Y:2005 | 02 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $16,917 | $0 | Implemented |
SD0362 # 03 Y:2005 | 03 | 2005 | INSTALL OCCUPANCY SENSORS | $14,251 | $3,500 | Implemented |
SD0362 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,614 | $26,000 | Implemented |
SD0362 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $749 | $80 | Implemented |
SD0362 # 06 Y:2005 | 06 | 2005 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $194,956 | $92,000 | Not Implemented |
SD0362 # 07 Y:2005 | 07 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,160 | $18,500 | Not Implemented |
SD0361 # 01 Y:2005 | 01 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,131 | $15,000 | Not Implemented |
SD0361 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,570 | $280 | Implemented |
SD0361 # 03 Y:2005 | 03 | 2005 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,916 | $144 | Implemented |
SD0361 # 04 Y:2005 | 04 | 2005 | INSTALL OCCUPANCY SENSORS | $390 | $170 | Implemented |
SD0361 # 05 Y:2005 | 05 | 2005 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $42,000 | $18,500 | Not Implemented |
SD0360 # 02 Y:2005 | 02 | 2005 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $82,741 | $534,444 | Not Implemented |