Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,946
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0326 # 09 Y:1987 | 09 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,989 | $600 | Implemented |
TN0319 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,035 | $2,880 | Implemented |
TN0319 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,706 | $0 | Implemented |
TN0319 # 05 Y:1987 | 05 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,556 | $240 | Implemented |
TN0319 # 07 Y:1987 | 07 | 1987 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $554 | $0 | Implemented |
TN0323 # 01 Y:1987 | 01 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,914 | $0 | Implemented |
TN0323 # 02 Y:1987 | 02 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,487 | $520 | Implemented |
TN0323 # 03 Y:1987 | 03 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,055 | $1,200 | Implemented |
TN0316 # 01 Y:1987 | 01 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,770 | $2,128 | Implemented |
TN0316 # 02 Y:1987 | 02 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $612 | $0 | Implemented |
TN0316 # 03 Y:1987 | 03 | 1987 | IMPROVE LUBRICATION PRACTICES | $3,136 | $3,000 | Implemented |
TN0316 # 05 Y:1987 | 05 | 1987 | INSULATE BARE EQUIPMENT | $2,271 | $4,080 | Implemented |
TN0316 # 06 Y:1987 | 06 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $254 | $300 | Implemented |
TN0316 # 07 Y:1987 | 07 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $515 | $800 | Implemented |
TN0316 # 08 Y:1987 | 08 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,099 | $150 | Implemented |
TN0316 # 09 Y:1987 | 09 | 1987 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $228 | $72 | Implemented |
TN0318 # 02 Y:1987 | 02 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $489 | $700 | Implemented |
TN0318 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,614 | $195 | Implemented |
TN0318 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $601 | $0 | Implemented |
TN0318 # 05 Y:1987 | 05 | 1987 | INSTALL SET-BACK TIMERS | $506 | $0 | Implemented |
TN0318 # 06 Y:1987 | 06 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $93 | $0 | Implemented |
TN0318 # 07 Y:1987 | 07 | 1987 | IMPROVE LUBRICATION PRACTICES | $158 | $300 | Implemented |
TN0320 # 01 Y:1987 | 01 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $16,448 | $3,192 | Implemented |
TN0320 # 04 Y:1987 | 04 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,392 | $800 | Implemented |
TN0320 # 05 Y:1987 | 05 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,300 | $210 | Implemented |