Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,950
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0664 # 03 Y:1999 | 03 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $473 | $825 | Not Implemented |
TN0664 # 04 Y:1999 | 04 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $67,500 | $16,375 | Implemented |
TN0664 # 05 Y:1999 | 05 | 1999 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $32,000 | $78,250 | Not Implemented |
TN0663 # 01 Y:1999 | 01 | 1999 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,379 | $13,600 | Implemented |
TN0663 # 02 Y:1999 | 02 | 1999 | INSTALL SKYLIGHTS | $4,132 | $7,350 | Not Implemented |
TN0663 # 03 Y:1999 | 03 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,603 | $800 | Not Implemented |
TN0663 # 04 Y:1999 | 04 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,041 | $0 | Implemented |
TN0663 # 05 Y:1999 | 05 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $992 | $750 | Implemented |
TN0663 # 06 Y:1999 | 06 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,950 | $800 | Implemented |
TN0663 # 07 Y:1999 | 07 | 1999 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $56,000 | $161,000 | Not Implemented |
TN0663 # 08 Y:1999 | 08 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $7,200 | $4,500 | Implemented |
TN0662 # 01 Y:1999 | 01 | 1999 | INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION | $55,900 | $90,000 | Not Implemented |
TN0662 # 02 Y:1999 | 02 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $45,000 | $30,000 | Implemented |
TN0662 # 03 Y:1999 | 03 | 1999 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $16,380 | $4,260 | Not Implemented |
TN0662 # 04 Y:1999 | 04 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $14,050 | $19,800 | Implemented |
TN0662 # 05 Y:1999 | 05 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,010 | $1,460 | Implemented |
TN0662 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $970 | $2,225 | Not Implemented |
TN0661 # 01 Y:1999 | 01 | 1999 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $175,335 | $5,000 | Implemented |
TN0661 # 02 Y:1999 | 02 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $91,400 | $49,760 | Not Implemented |
TN0661 # 03 Y:1999 | 03 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $73,031 | $8,750 | Not Implemented |
TN0661 # 04 Y:1999 | 04 | 1999 | OPTIMIZE PLANT POWER FACTOR | $72,160 | $93,000 | Not Implemented |
TN0661 # 05 Y:1999 | 05 | 1999 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $39,290 | $2,720 | Not Implemented |
TN0661 # 06 Y:1999 | 06 | 1999 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $25,103 | $30,600 | Implemented |
TN0661 # 07 Y:1999 | 07 | 1999 | METER WASTE WATER | $13,500 | $3,700 | Not Implemented |
TN0661 # 08 Y:1999 | 08 | 1999 | INSTALL TIMERS AND/OR THERMOSTATS | $6,500 | $650 | Not Implemented |