Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,950

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0576 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $867 $215 Not Implemented
TN0576 # 06 Y:1996 06 1996 INSTALL TIMERS AND/OR THERMOSTATS $809 $420 Implemented
TN0575 # 01 Y:1996 01 1996 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $214,400 $208,880 Not Implemented
TN0575 # 02 Y:1996 02 1996 INCREASE USE OF AUTOMATION $87,771 $254,000 Implemented
TN0575 # 03 Y:1996 03 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,294 $8,300 Implemented
TN0575 # 04 Y:1996 04 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,637 $2,500 Implemented
TN0575 # 05 Y:1996 05 1996 INSTALL TIMERS AND/OR THERMOSTATS $1,240 $580 Not Implemented
TN0575 # 06 Y:1996 06 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $112 $175 Implemented
TN0573 # 01 Y:1996 01 1996 USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS $14,000 $65,000 Implemented
TN0573 # 02 Y:1996 02 1996 UPGRADE CONVEYORS $9,029 $10,700 Not Implemented
TN0573 # 03 Y:1996 03 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $2,596 $7,980 Not Implemented
TN0573 # 04 Y:1996 04 1996 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $369 $430 Not Implemented
TN0573 # 05 Y:1996 05 1996 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $203 $560 Implemented
TN0573 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $195 $140 Implemented
TN0573 # 07 Y:1996 07 1996 USE SYNTHETIC LUBRICANT $182 $0 Implemented
TN0574 # 01 Y:1996 01 1996 $115,000 $140,000 Not Implemented
TN0574 # 02 Y:1996 02 1996 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $79,000 $22,000 Implemented
TN0574 # 03 Y:1996 03 1996 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $36,000 $600 Not Implemented
TN0574 # 04 Y:1996 04 1996 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER $7,000 $0 Not Implemented
TN0574 # 05 Y:1996 05 1996 ELIMINATE/REDUCE AN OPERATION $5,000 $9,000 Not Implemented
TN0574 # 06 Y:1996 06 1996 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,000 $0 Implemented
TN0574 # 07 Y:1996 07 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $500 $300 Implemented
TN0572 # 01 Y:1996 01 1996 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $149,480 $150,000 Not Implemented
TN0572 # 02 Y:1996 02 1996 USE DEMAND CONTROLLER OR LOAD SHEDDER $13,909 $15,800 Implemented
TN0572 # 03 Y:1996 03 1996 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $1,987 $0 Implemented