Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
398
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0646 # 05 Y:1998 | 05 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,880 | $0 | Implemented |
TN0646 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,325 | $5,000 | Implemented |
TN0646 # 03 Y:1998 | 03 | 1998 | ADD AREA LIGHTING SWITCHES | $8,900 | $13,600 | Implemented |
TN0646 # 02 Y:1998 | 02 | 1998 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $28,800 | $21,900 | Implemented |
TN0646 # 01 Y:1998 | 01 | 1998 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $603,410 | $51,350 | Implemented |
TN0639 # 04 Y:1998 | 04 | 1998 | RECOVER AND REUSE WASTE MATERIAL | $1,200 | $0 | Implemented |
TN0639 # 06 Y:1998 | 06 | 1998 | USE OPTIMUM THICKNESS INSULATION | $470 | $1,125 | Not Implemented |
TN0639 # 05 Y:1998 | 05 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $754 | $950 | Implemented |
TN0639 # 03 Y:1998 | 03 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $4,680 | $0 | Implemented |
TN0639 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $5,440 | $3,440 | Implemented |
TN0639 # 01 Y:1998 | 01 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $74,290 | $26,180 | Implemented |
TN0634 # 13 Y:1998 | 13 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $310 | $500 | Implemented |
TN0634 # 12 Y:1998 | 12 | 1998 | REPAIR AND ELIMINATE STEAM LEAKS | $310 | $295 | Implemented |
TN0634 # 11 Y:1998 | 11 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $320 | $960 | Implemented |
TN0634 # 10 Y:1998 | 10 | 1998 | INSULATE BARE EQUIPMENT | $430 | $390 | Not Implemented |
TN0634 # 09 Y:1998 | 09 | 1998 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,038 | $1,820 | Implemented |
TN0634 # 08 Y:1998 | 08 | 1998 | AIR CONDITION ONLY SPACE NECESSARY | $1,310 | $0 | Not Implemented |
TN0634 # 07 Y:1998 | 07 | 1998 | USE MINIMUM STEAM OPERATING PRESSURE | $1,460 | $0 | Not Implemented |
TN0634 # 06 Y:1998 | 06 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $1,990 | $510 | Implemented |
TN0634 # 05 Y:1998 | 05 | 1998 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $2,990 | $8,575 | Not Implemented |
TN0634 # 04 Y:1998 | 04 | 1998 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,600 | $0 | Not Implemented |
TN0634 # 03 Y:1998 | 03 | 1998 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,720 | $2,600 | Implemented |
TN0634 # 02 Y:1998 | 02 | 1998 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $67,500 | $50,000 | Implemented |
TN0634 # 01 Y:1998 | 01 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $84,680 | $200,000 | Implemented |
TN0632 # 07 Y:1998 | 07 | 1998 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $32,400 | $47,100 | Implemented |