Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,950
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0652 # 08 Y:1999 | 08 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $96,250 | $400,000 | Not Implemented |
TN0652 # 09 Y:1999 | 09 | 1999 | REPAIR AND ELIMINATE STEAM LEAKS | $28,970 | $300 | Not Implemented |
TN0652 # 10 Y:1999 | 10 | 1999 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $16,210 | $10,000 | Not Implemented |
TN0680 # 01 Y:2000 | 01 | 2000 | BURN A LESS EXPENSIVE GRADE OF FUEL | $75,400 | $400,000 | Not Implemented |
TN0680 # 02 Y:2000 | 02 | 2000 | MODIFY CURRENT INCENTIVE PROGRAM | $37,500 | $16,430 | Implemented |
TN0680 # 03 Y:2000 | 03 | 2000 | DEVELOP A REPAIR/REPLACE POLICY | $30,832 | $1,075 | Not Implemented |
TN0680 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,356 | $18,370 | Not Implemented |
TN0680 # 05 Y:2000 | 05 | 2000 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $2,810 | $500 | Implemented |
TN0680 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $960 | $0 | Not Implemented |
TN0650 # 01 Y:1999 | 01 | 1999 | MODIFY CURRENT INCENTIVE PROGRAM | $150,000 | $30,000 | Not Implemented |
TN0650 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $8,400 | $0 | Implemented |
TN0650 # 03 Y:1999 | 03 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $8,150 | $0 | Implemented |
TN0650 # 04 Y:1999 | 04 | 1999 | INSULATE BARE EQUIPMENT | $6,220 | $2,180 | Not Implemented |
TN0650 # 05 Y:1999 | 05 | 1999 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $6,350 | $36,000 | Not Implemented |
TN0650 # 06 Y:1999 | 06 | 1999 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,960 | $16,600 | Not Implemented |
TN0650 # 07 Y:1999 | 07 | 1999 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $39,640 | $30,500 | Not Implemented |
TN0650 # 08 Y:1999 | 08 | 1999 | USE MINIMUM STEAM OPERATING PRESSURE | $5,280 | $0 | Not Implemented |
TN0650 # 09 Y:1999 | 09 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,555 | $1,120 | Not Implemented |
TN0677 # 01 Y:2000 | 01 | 2000 | INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION | $30,000 | $30,000 | Not Implemented |
TN0677 # 02 Y:2000 | 02 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,356 | $5,625 | Implemented |
TN0677 # 03 Y:2000 | 03 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $4,766 | $15,450 | Not Implemented |
TN0677 # 04 Y:2000 | 04 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,820 | $1,075 | Not Implemented |
TN0677 # 05 Y:2000 | 05 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,440 | $3,180 | Not Implemented |
TN0677 # 06 Y:2000 | 06 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,174 | $240 | Not Implemented |
TN0679 # 01 Y:2000 | 01 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $164,700 | $600 | Implemented |