Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
123
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0727 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $25,195 | $31,250 | Implemented |
UD0727 # 01 Y:2005 | 01 | 2005 | USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS | $41,013 | $0 | Implemented |
UD0727 # 05 Y:2005 | 05 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,131 | $0 | Implemented |
UD0727 # 04 Y:2005 | 04 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,196 | $15,000 | Implemented |
UD0726 # 13 Y:2005 | 13 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $3,679 | $0 | Implemented |
UD0726 # 17 Y:2005 | 17 | 2005 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $412 | $960 | Implemented |
UD0726 # 16 Y:2005 | 16 | 2005 | UPGRADE CONTROLS ON COMPRESSORS | $1,253 | $0 | Implemented |
UD0726 # 15 Y:2005 | 15 | 2005 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $1,554 | $0 | Implemented |
UD0726 # 12 Y:2005 | 12 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,280 | $736 | Implemented |
UD0726 # 11 Y:2005 | 11 | 2005 | COVER OPEN TANKS | $4,429 | $1,200 | Implemented |
UD0726 # 10 Y:2005 | 10 | 2005 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,819 | $12,560 | Implemented |
UD0726 # 07 Y:2005 | 07 | 2005 | INSULATE BARE EQUIPMENT | $19,788 | $4,000 | Implemented |
UD0726 # 06 Y:2005 | 06 | 2005 | REDUCE VENTILATION AIR | $26,800 | $0 | Implemented |
UD0726 # 05 Y:2005 | 05 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,707 | $93,840 | Implemented |
UD0726 # 04 Y:2005 | 04 | 2005 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $93,662 | $72,100 | Implemented |
UD0726 # 01 Y:2005 | 01 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $222,216 | $3,730 | Implemented |
UD0725 # 04 Y:2005 | 04 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,772 | $18,444 | Implemented |
UD0725 # 09 Y:2005 | 09 | 2005 | INSTALL OCCUPANCY SENSORS | $1,788 | $728 | Implemented |
UD0725 # 03 Y:2005 | 03 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $6,863 | $28,350 | Implemented |
UD0725 # 08 Y:2005 | 08 | 2005 | INSULATE BARE EQUIPMENT | $1,968 | $0 | Implemented |
UD0725 # 05 Y:2005 | 05 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,315 | $1,320 | Implemented |
UD0724 # 11 Y:2005 | 11 | 2005 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $471 | $880 | Implemented |
UD0724 # 09 Y:2005 | 09 | 2005 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $3,364 | $0 | Implemented |
UD0724 # 04 Y:2005 | 04 | 2005 | INSULATE BARE EQUIPMENT | $13,563 | $6,505 | Implemented |
UD0724 # 03 Y:2005 | 03 | 2005 | USE PHOTOCELL CONTROLS | $16,400 | $0 | Implemented |