IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,094

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0107 # 02 Y:1998 02 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $250 $250 Not Implemented
UM0107 # 03 Y:1998 03 1998 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $7,179 $250 Not Implemented
UM0107 # 04 Y:1998 04 1998 CONTRACT A WOOD PALLET RECYCLING COMPANY $130 $100 Not Implemented
UM0107 # 05 Y:1998 05 1998 MOVE PRODUCT USING MECHANICAL MEANS $10,400 $2,250 Not Implemented
UM0107 # 06 Y:1998 06 1998 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $14,550 $5,200 Not Implemented
UM0105 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,866 $14,437 Implemented
UM0105 # 02 Y:1998 02 1998 USE RADIANT HEATER FOR SPOT HEATING $20,994 $33,960 Not Implemented
UM0105 # 03 Y:1998 03 1998 ELIMINATE LEAKS IN WATER LINES AND VALVES $1,171 $600 Not Implemented
UM0105 # 04 Y:1998 04 1998 ELIMINATE LEAKS IN WATER LINES AND VALVES $8,426 $642 Not Implemented
UM0105 # 05 Y:1998 05 1998 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $15,625 $58,992 Implemented
UM0104 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $249 $540 Implemented
UM0104 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,708 $8,483 Implemented
UM0104 # 03 Y:1998 03 1998 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,449 $0 Implemented
UM0104 # 04 Y:1998 04 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $801 $100 Implemented
UM0104 # 05 Y:1998 05 1998 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $8,468 $6,750 Implemented
UM0104 # 06 Y:1998 06 1998 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $13,420 $5,200 Implemented
UM0104 # 07 Y:1998 07 1998 REDUCE SCRAP PRODUCTION $1,690 $500 Implemented
UM0104 # 08 Y:1998 08 1998 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS $8,160 $2,500 Implemented
UM0103 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $173 $157 Not Implemented
UM0103 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,518 $3,418 Not Implemented
UM0103 # 03 Y:1998 03 1998 INSTALL OCCUPANCY SENSORS $490 $500 Not Implemented
UM0103 # 04 Y:1998 04 1998 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,733 $0 Not Implemented
UM0103 # 05 Y:1998 05 1998 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $15,000 $1,500 Not Implemented
UM0103 # 06 Y:1998 06 1998 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS $1,435 $4,535 Not Implemented
UM0103 # 07 Y:1998 07 1998 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $1,962 $200 Implemented