Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,732

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0184 # 05 Y:2001 05 2001 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $56,800 $75,000 Implemented
UM0184 # 06 Y:2001 06 2001 CHANGE OPERATING CONDITIONS $6,800 $11,000 Not Implemented
UM0186 # 01 Y:2001 01 2001 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $21,500 $4,100 n/a
UM0186 # 02 Y:2001 02 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,000 $3,500 n/a
UM0186 # 03 Y:2001 03 2001 INSULATE BARE EQUIPMENT $7,700 $700 n/a
UM0186 # 04 Y:2001 04 2001 RECOVER WASTE HEAT FROM EQUIPMENT $1,100 $500 n/a
UM0186 # 05 Y:2001 05 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,000 $300 n/a
UM0186 # 06 Y:2001 06 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,000 $700 n/a
UM0186 # 07 Y:2001 07 2001 OPTIMIZE PLANT POWER FACTOR $1,500 $2,300 n/a
UM0186 # 08 Y:2001 08 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $500 $1,000 n/a
UM0182 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $568 $375 Implemented
UM0182 # 02 Y:2001 02 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $361 $1,000 Not Implemented
UM0182 # 03 Y:2001 03 2001 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR $57,900 $28,900 Implemented
UM0182 # 04 Y:2001 04 2001 RECOVER WASTE HEAT FROM EQUIPMENT $43,000 $100,000 Not Implemented
UM0181 # 01 Y:2001 01 2001 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $300 $300 Not Implemented
UM0181 # 02 Y:2001 02 2001 USE OPTIMUM THICKNESS INSULATION $3,470 $3,540 Not Implemented
UM0181 # 03 Y:2001 03 2001 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $94,100 $71,000 Not Implemented
UM0181 # 04 Y:2001 04 2001 IMPROVE SPACE COMFORT CONDITIONING $4,520 $8,000 Not Implemented
UM0180 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,540 $750 Implemented
UM0180 # 02 Y:2001 02 2001 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $1,120 $2,100 Implemented
UM0180 # 03 Y:2001 03 2001 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $6,580 $950 Implemented
UM0180 # 04 Y:2001 04 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $54,000 $16,000 Implemented
UM0179 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,864 $450 Implemented
UM0179 # 02 Y:2001 02 2001 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $994 $1,250 Not Implemented
UM0179 # 03 Y:2001 03 2001 USE OPTIMUM THICKNESS INSULATION $4,406 $2,264 Not Implemented