IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

187

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0326 # 03 Y:1998 03 1998 USE DEMAND CONTROLLER OR LOAD SHEDDER $11,269 $20,000 Not Implemented
WI0326 # 04 Y:1998 04 1998 REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF $7,874 $12,186 Not Implemented
WI0326 # 05 Y:1998 05 1998 USE A RAG RECYCLE SERVICE $4,430 $0 Not Implemented
WI0326 # 06 Y:1998 06 1998 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,348 $12,500 Not Implemented
WI0326 # 07 Y:1998 07 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,948 $740 Not Implemented
WI0326 # 08 Y:1998 08 1998 INSTALL TIMERS AND/OR THERMOSTATS $504 $400 Not Implemented
WI0326 # 09 Y:1998 09 1998 INSULATE BARE EQUIPMENT $321 $46 Not Implemented
WI0326 # 10 Y:1998 10 1998 REMOVE SLUDGE FROM TANKS ON A REGULAR BASIS $300 $0 Not Implemented
WI0325 # 01 Y:1998 01 1998 $336,000 $240,000 Not Implemented
WI0325 # 02 Y:1998 02 1998 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $7,848 $500 Implemented
WI0325 # 03 Y:1998 03 1998 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,598 $10,000 Not Implemented
WI0325 # 04 Y:1998 04 1998 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $5,590 $0 Not Implemented
WI0325 # 05 Y:1998 05 1998 $1,652 $0 Not Implemented
WI0325 # 06 Y:1998 06 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $756 $740 Not Implemented
WI0324 # 01 Y:1998 01 1998 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $3,936 $0 Not Implemented
WI0324 # 02 Y:1998 02 1998 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $487 $0 Implemented
WI0324 # 03 Y:1998 03 1998 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,780 $850 Not Implemented
WI0324 # 04 Y:1998 04 1998 RECOVER WASTE HEAT FROM EQUIPMENT $1,054 $400 Implemented
WI0324 # 05 Y:1998 05 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $381 $90 Implemented
WI0324 # 06 Y:1998 06 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $372 $640 Implemented
WI0324 # 07 Y:1998 07 1998 REPLACE CLOTH RAGS WITH PAPER TOWELS $1,039 $0 Not Implemented
WI0323 # 01 Y:1998 01 1998 TREAT AND REUSE RINSE WATERS $6,555 $1,475 Not Implemented
WI0323 # 02 Y:1998 02 1998 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS $2,629 $0 Implemented
WI0323 # 03 Y:1998 03 1998 INSTALL TIMERS AND/OR THERMOSTATS $2,343 $600 Not Implemented
WI0323 # 04 Y:1998 04 1998 $820 $0 Implemented