Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
104
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0208 # 12 Y:1998 | 12 | 1998 | CLEAR AND RENT EXISTING SPACE | $13,843 | $0 | Implemented |
UF0208 # 11 Y:1998 | 11 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $24,315 | $50 | Implemented |
UF0208 # 07 Y:1998 | 07 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,269 | $0 | Implemented |
UF0208 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,451 | $2,600 | Implemented |
UF0207 # 10 Y:1998 | 10 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $31,783 | $5,000 | Implemented |
UF0207 # 09 Y:1998 | 09 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $5,662 | $0 | Implemented |
UF0207 # 06 Y:1998 | 06 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,587 | $0 | Implemented |
UF0207 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,914 | $1,700 | Implemented |
UF0207 # 01 Y:1998 | 01 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,410 | $0 | Implemented |
UF0206 # 13 Y:1998 | 13 | 1998 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $2,096 | $0 | Implemented |
UF0206 # 06 Y:1998 | 06 | 1998 | REPAIR AND ELIMINATE STEAM LEAKS | $42,698 | $320 | Implemented |
UF0206 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,741 | $1,160 | Implemented |
UF0206 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $3,113 | $5,880 | Implemented |
UF0205 # 06 Y:1998 | 06 | 1998 | OPTIMIZE PLANT POWER FACTOR | $13,598 | $40,806 | Implemented |
UF0205 # 01 Y:1998 | 01 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,940 | $10,390 | Implemented |
UF0205 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $20,997 | $3,200 | Implemented |
UF0205 # 04 Y:1998 | 04 | 1998 | OPTIMIZE PLANT POWER FACTOR | $31,516 | $22,000 | Implemented |
UF0205 # 05 Y:1998 | 05 | 1998 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,075 | $471 | Implemented |
UF0205 # 09 Y:1998 | 09 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $9,360 | $10,320 | Implemented |
UF0205 # 10 Y:1998 | 10 | 1998 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $17,160 | $10,000 | Implemented |
UF0205 # 11 Y:1998 | 11 | 1998 | UPGRADE CONVEYORS | $84,000 | $10,500 | Implemented |
UF0204 # 05 Y:1998 | 05 | 1998 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $46,067 | $116,000 | Implemented |
UF0204 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,991 | $5,652 | Implemented |
UF0204 # 04 Y:1998 | 04 | 1998 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $980 | $1,000 | Implemented |
UF0204 # 06 Y:1998 | 06 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,919 | $1,200 | Implemented |