IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

157

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0279 # 08 Y:2001 08 2001 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,800 $0 Implemented
UF0279 # 07 Y:2001 07 2001 INSTALL OCCUPANCY SENSORS $2,853 $767 Implemented
UF0279 # 05 Y:2001 05 2001 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $2,260 $0 Implemented
UF0279 # 04 Y:2001 04 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,241 $1,520 Implemented
UF0279 # 01 Y:2001 01 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $9,057 $10,208 Implemented
UF0278 # 04 Y:2001 04 2001 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $56,760 $143,877 Implemented
UF0278 # 03 Y:2001 03 2001 INSTALL OCCUPANCY SENSORS $703 $621 Implemented
UF0278 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $190,612 $67,472 Implemented
UF0277 # 13 Y:2001 13 2001 INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM $7,281 $0 Implemented
UF0277 # 11 Y:2001 11 2001 REPAIR OR REPLACE STEAM TRAPS $2,712 $0 Implemented
UF0277 # 08 Y:2001 08 2001 DEVELOP A REPAIR/REPLACE POLICY $8,088 $0 Implemented
UF0277 # 02 Y:2001 02 2001 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,130 $0 Implemented
UF0277 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,104 $0 Implemented
MI0018 # 01 Y:2001 01 2001 INSTALL SET-BACK TIMERS $7,803 $7,764 Implemented
MI0018 # 07 Y:2001 07 2001 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,065 $13 Implemented
MI0018 # 06 Y:2001 06 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,572 $208 Implemented
MI0018 # 05 Y:2001 05 2001 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $12,698 $13 Implemented
MI0018 # 04 Y:2001 04 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $8,070 $312 Implemented
MI0018 # 03 Y:2001 03 2001 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $34,167 $13 Implemented
MI0018 # 02 Y:2001 02 2001 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,179 $208 Implemented
UF0276 # 08 Y:2001 08 2001 INSTALL STEAM TRAP $14,111 $1,200 Implemented
UF0276 # 09 Y:2001 09 2001 DISTILL CONTAMINATED SOLVENTS FOR REUSE $21,330 $45,000 Implemented
UF0276 # 02 Y:2001 02 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $516 $500 Implemented
UF0276 # 06 Y:2001 06 2001 INCREASE AMOUNT OF CONDENSATE RETURNED $1,194 $5,000 Implemented
UF0276 # 04 Y:2001 04 2001 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES $439 $450 Implemented