Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
257
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0142 # 06 Y:1984 | 06 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,842 | $5,000 | Implemented |
KU0142 # 13 Y:1984 | 13 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,360 | $3,500 | Implemented |
KU0144 # 10 Y:1984 | 10 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $753 | $400 | Implemented |
KU0144 # 09 Y:1984 | 09 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,039 | $500 | Implemented |
KU0144 # 08 Y:1984 | 08 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $160 | $0 | Implemented |
KU0144 # 07 Y:1984 | 07 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,279 | $39 | Implemented |
KU0144 # 05 Y:1984 | 05 | 1984 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,578 | $0 | Implemented |
KU0142 # 07 Y:1984 | 07 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,608 | $1,500 | Implemented |
KU0144 # 03 Y:1984 | 03 | 1984 | IMPROVE LUBRICATION PRACTICES | $1,597 | $0 | Implemented |
KU0144 # 02 Y:1984 | 02 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $3,395 | $4,000 | Implemented |
KU0143 # 13 Y:1984 | 13 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $183 | $0 | Implemented |
KU0143 # 05 Y:1984 | 05 | 1984 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $4,141 | $2,000 | Implemented |
KU0143 # 10 Y:1984 | 10 | 1984 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $620 | $920 | Implemented |
KU0142 # 14 Y:1984 | 14 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,883 | $75 | Implemented |
KU0142 # 16 Y:1984 | 16 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,606 | $0 | Implemented |
KU0142 # 19 Y:1984 | 19 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $506 | $0 | Implemented |
KU0143 # 02 Y:1984 | 02 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,840 | $0 | Implemented |
KU0143 # 04 Y:1984 | 04 | 1984 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,586 | $3,000 | Implemented |
KU0143 # 01 Y:1984 | 01 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,486 | $0 | Implemented |
KU0133 # 16 Y:1984 | 16 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $378 | $0 | Implemented |
KU0133 # 15 Y:1984 | 15 | 1984 | INSULATE BARE EQUIPMENT | $626 | $450 | Implemented |
KU0133 # 14 Y:1984 | 14 | 1984 | INSULATE BARE EQUIPMENT | $669 | $400 | Implemented |
KU0133 # 11 Y:1984 | 11 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,316 | $450 | Implemented |
KU0133 # 10 Y:1984 | 10 | 1984 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,584 | $2,900 | Implemented |
KU0133 # 13 Y:1984 | 13 | 1984 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,562 | $0 | Implemented |