Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
78
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0134 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,068 | $210 | Implemented |
LL0133 # 08 Y:2002 | 08 | 2002 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $3,076 | $0 | Implemented |
LL0133 # 07 Y:2002 | 07 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $240 | $0 | Implemented |
LL0133 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $269 | $150 | Implemented |
LL0133 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $483 | $0 | Implemented |
LL0133 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $974 | $249 | Implemented |
LL0133 # 02 Y:2002 | 02 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,061 | $0 | Implemented |
LL0132 # 04 Y:2002 | 04 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $601 | $418 | Implemented |
LL0131 # 03 Y:2002 | 03 | 2002 | INSTALL SET-BACK TIMERS | $909 | $1,097 | Implemented |
LL0130 # 08 Y:2002 | 08 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $45,027 | $0 | Implemented |
LL0130 # 07 Y:2002 | 07 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $600 | $0 | Implemented |
LL0130 # 05 Y:2002 | 05 | 2002 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $1,728 | $621 | Implemented |
LL0130 # 04 Y:2002 | 04 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,838 | $0 | Implemented |
LL0130 # 02 Y:2002 | 02 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,729 | $2,340 | Implemented |
LL0130 # 01 Y:2002 | 01 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,705 | $0 | Implemented |
LL0129 # 06 Y:2002 | 06 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $29,381 | $28,907 | Implemented |
LL0129 # 01 Y:2002 | 01 | 2002 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $191,600 | $22,000 | Implemented |
LL0129 # 05 Y:2002 | 05 | 2002 | OPTIMIZE PLANT POWER FACTOR | $121,713 | $95,025 | Implemented |
LL0129 # 07 Y:2002 | 07 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $52,853 | $12,720 | Implemented |
LL0129 # 08 Y:2002 | 08 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $36,741 | $7,200 | Implemented |
LL0128 # 05 Y:2002 | 05 | 2002 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,123 | $0 | Implemented |
LL0128 # 02 Y:2002 | 02 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,887 | $93,094 | Implemented |
LL0128 # 01 Y:2002 | 01 | 2002 | CONVERT TO OXYFUEL BURNERS | $235,855 | $281,796 | Implemented |
LL0127 # 05 Y:2002 | 05 | 2002 | OPTIMIZE PLANT POWER FACTOR | $1,970 | $6,440 | Implemented |
LL0127 # 04 Y:2002 | 04 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $6,088 | $900 | Implemented |