Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,142
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MZ0057 # 08 Y:2010 | 08 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $186 | $300 | Implemented |
MZ0057 # 09 Y:2010 | 09 | 2010 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $2,104 | $100 | Implemented |
MZ0057 # 10 Y:2010 | 10 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,259 | $0 | Implemented |
MZ0057 # 11 Y:2010 | 11 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,919 | $1,300 | Implemented |
MZ0057 # 12 Y:2010 | 12 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,016 | $0 | Implemented |
MZ0057 # 13 Y:2010 | 13 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,940 | $0 | Implemented |
MZ0057 # 14 Y:2010 | 14 | 2010 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $3,194 | $2,000 | Implemented |
MZ0057 # 16 Y:2010 | 16 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $52 | $50 | Implemented |
MZ0057 # 18 Y:2010 | 18 | 2010 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $12,000 | $0 | Implemented |
MZ0057 # 19 Y:2010 | 19 | 2010 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $19,660 | $18,000 | Implemented |
MZ0057 # 21 Y:2010 | 21 | 2010 | INSULATE BARE EQUIPMENT | $248 | $300 | Implemented |
MZ0053 # 01 Y:2010 | 01 | 2010 | REPLACE BOILER | $33,880 | $115,000 | Implemented |
MZ0053 # 02 Y:2010 | 02 | 2010 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $959 | $1,000 | Implemented |
MZ0053 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $22,455 | $10,000 | Implemented |
MZ0053 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,022 | $33,660 | Implemented |
MZ0053 # 05 Y:2010 | 05 | 2010 | INSTALL OCCUPANCY SENSORS | $888 | $1,550 | Implemented |
MZ0053 # 06 Y:2010 | 06 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $987 | $0 | Implemented |
MZ0053 # 07 Y:2010 | 07 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,342 | $1,160 | Implemented |
MZ0053 # 08 Y:2010 | 08 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,601 | $0 | Implemented |
MZ0053 # 09 Y:2010 | 09 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,207 | $0 | Implemented |
MZ0053 # 10 Y:2010 | 10 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,916 | $1,100 | Implemented |
MZ0053 # 11 Y:2010 | 11 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $14,987 | $5,000 | Implemented |
MZ0050 # 02 Y:2010 | 02 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,616 | $0 | Implemented |
MZ0050 # 03 Y:2010 | 03 | 2010 | AIR CONDITION ONLY SPACE NECESSARY | $24,897 | $5,000 | Implemented |
MZ0050 # 04 Y:2010 | 04 | 2010 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $585 | $6,000 | Implemented |