Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,628
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0415 # 08 Y:2010 | 08 | 2010 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,733 | $700 | Implemented |
WV0415 # 10 Y:2010 | 10 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,852 | $884 | Implemented |
WV0415 # 11 Y:2010 | 11 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,398 | $4,490 | Implemented |
WV0415 # 12 Y:2010 | 12 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,032 | $1,312 | Implemented |
WV0411 # 02 Y:2010 | 02 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,172 | $6,123 | Implemented |
WV0411 # 03 Y:2010 | 03 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,958 | $3,705 | Implemented |
UD0823 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $17,201 | $7,375 | Implemented |
UD0823 # 08 Y:2010 | 08 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,268 | $25 | Implemented |
UD0823 # 10 Y:2010 | 10 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $524 | $25 | Implemented |
UD0823 # 13 Y:2010 | 13 | 2010 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $10,010 | $50,050 | Implemented |
UD0823 # 15 Y:2010 | 15 | 2010 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $355 | $25 | Implemented |
UD0822 # 10 Y:2010 | 10 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,483 | $63 | Implemented |
UM0372 # 01 Y:2010 | 01 | 2010 | INSTALL OCCUPANCY SENSORS | $2,083 | $2,500 | Implemented |
UM0372 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,092 | $25,000 | Implemented |
UM0372 # 03 Y:2010 | 03 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $265 | $2,000 | Implemented |
UM0372 # 04 Y:2010 | 04 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $645 | $200 | Implemented |
UM0372 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $88 | $1,000 | Implemented |
UM0372 # 06 Y:2010 | 06 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,702 | $3,500 | Implemented |
UM0372 # 07 Y:2010 | 07 | 2010 | COVER OPEN TANKS | $17,216 | $7,182 | Implemented |
UM0372 # 08 Y:2010 | 08 | 2010 | COVER OPEN TANKS | $10,159 | $500 | Implemented |
UM0372 # 09 Y:2010 | 09 | 2010 | COVER OPEN TANKS | $9,602 | $2,472 | Implemented |
UD0821 # 01 Y:2010 | 01 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $4,575 | $300,000 | Implemented |
UD0821 # 02 Y:2010 | 02 | 2010 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,610 | $25 | Implemented |
UD0821 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,341 | $60,300 | Implemented |
UD0821 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $479 | $893 | Implemented |