Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,643

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0062 # 01 Y:1992 01 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,190 $800 Implemented
AS0062 # 02 Y:1992 02 1992 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $1,689 $8,870 Implemented
AS0062 # 03 Y:1992 03 1992 PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT $222 $320 Implemented
AS0062 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $469 $1,293 Implemented
AS0062 # 05 Y:1992 05 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $100 $606 Implemented
AS0062 # 06 Y:1992 06 1992 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $4,458 $25,000 Implemented
AS0062 # 07 Y:1992 07 1992 INSULATE BARE EQUIPMENT $607 $183 Implemented
AS0062 # 08 Y:1992 08 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $636 $100 Implemented
AS0058 # 01 Y:1992 01 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $40,257 $64,053 Implemented
AS0058 # 02 Y:1992 02 1992 USE HEAT PUMP FOR SPACE CONDITIONING $33,994 $182,325 Implemented
AS0058 # 03 Y:1992 03 1992 PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT $2,531 $3,100 Implemented
AS0058 # 04 Y:1992 04 1992 RECOVER WASTE HEAT FROM EQUIPMENT $776 $1,400 Implemented
AS0058 # 05 Y:1992 05 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,087 $200 Implemented
AS0058 # 06 Y:1992 06 1992 REDUCE VENTILATION AIR $470 $400 Implemented
AS0058 # 07 Y:1992 07 1992 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS $539 $114 Implemented
AS0058 # 08 Y:1992 08 1992 INSULATE BARE EQUIPMENT $273 $100 Implemented
AS0058 # 09 Y:1992 09 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,036 $3,213 Implemented
AS0058 # 10 Y:1992 10 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $475 $0 Implemented
AS0054 # 02 Y:1992 02 1992 USE UTILITY CONTROLLED POWER MANAGEMENT $12,703 $25,000 Implemented
AS0054 # 03 Y:1992 03 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,278 $18,136 Implemented
AS0054 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,936 $1,803 Implemented
AS0054 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15 $147 Implemented
AS0054 # 07 Y:1992 07 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,880 $100 Implemented
AS0053 # 04 Y:1992 04 1992 INSULATE BARE EQUIPMENT $12,327 $5,772 Implemented
AS0053 # 05 Y:1992 05 1992 INSTALL / REPAIR INSULATION ON STEAM LINES $2,693 $989 Implemented