Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,871
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ND0236 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,954 | $10,215 | Implemented |
ND0236 # 06 Y:1995 | 06 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $588 | $200 | Implemented |
ND0235 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,195 | $529 | Implemented |
ND0235 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $55,146 | $30,640 | Implemented |
ND0235 # 06 Y:1995 | 06 | 1995 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $399,646 | $125,000 | Implemented |
ND0235 # 07 Y:1995 | 07 | 1995 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $15,000 | $30,000 | Implemented |
ND0232 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $580 | $200 | Implemented |
ND0232 # 05 Y:1995 | 05 | 1995 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $11,506 | $5,000 | Implemented |
ND0232 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,430 | $6,690 | Implemented |
ND0232 # 08 Y:1995 | 08 | 1995 | TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS | $7,136 | $44,552 | Implemented |
ND0233 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,844 | $9,060 | Implemented |
ND0233 # 04 Y:1995 | 04 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,924 | $319 | Implemented |
ND0234 # 02 Y:1995 | 02 | 1995 | HEAT TREAT PARTS ONLY TO REQUIRED SPECIFICATIONS OR STANDARDS | $1,082 | $500 | Implemented |
ND0234 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $772 | $150 | Implemented |
ND0234 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $201 | $250 | Implemented |
ND0234 # 06 Y:1995 | 06 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $101 | $0 | Implemented |
ND0234 # 07 Y:1995 | 07 | 1995 | TREAT AND REUSE RINSE WATERS | $27,000 | $45,000 | Implemented |
ND0234 # 08 Y:1995 | 08 | 1995 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $7,300 | $400 | Implemented |
ND0234 # 09 Y:1995 | 09 | 1995 | USE ALTERNATIVE FLOCCULENT TO MINIMIZE SLUDGE VOLUME | $650 | $3,500 | Implemented |
ND0227 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,694 | $934 | Implemented |
ND0227 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,252 | $900 | Implemented |
ND0227 # 02 Y:1995 | 02 | 1995 | OPTIMIZE PLANT POWER FACTOR | $37,071 | $47,040 | Implemented |
ND0227 # 03 Y:1995 | 03 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,317 | $2,000 | Implemented |
ND0227 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $67,735 | $44,850 | Implemented |
ND0230 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,172 | $792 | Implemented |