IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,260

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0598 # 02 Y:2007 02 2007 IMPROVE COMBUSTION CONTROL CAPABILITY $37,380 $112,000 Not Implemented
CO0598 # 03 Y:2007 03 2007 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT $15,090 $338,400 Not Implemented
CO0598 # 04 Y:2007 04 2007 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $8,960 $14,520 Not Implemented
CO0598 # 05 Y:2007 05 2007 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,660 $4,250 Not Implemented
CO0598 # 06 Y:2007 06 2007 USE SOLAR HEAT TO MAKE ELECTRICTY $1,310 $11,000 Not Implemented
MZ0001 # 01 Y:2007 01 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $25,357 $20,580 Not Implemented
MZ0001 # 02 Y:2007 02 2007 Hardware $75,000 $78,000 Implemented
MZ0001 # 03 Y:2007 03 2007 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $3,400 $800 Implemented
MZ0001 # 04 Y:2007 04 2007 Hardware $24,000 $78,000 Not Implemented
MZ0001 # 05 Y:2007 05 2007 INSTALL / REPAIR INSULATION ON STEAM LINES $3,915 $3,300 Implemented
UA0001 # 01 Y:2007 01 2007 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,286 $252 Not Implemented
UA0001 # 02 Y:2007 02 2007 RECOVER WASTE HEAT FROM EQUIPMENT $1,116 $3,113 Not Implemented
UA0001 # 03 Y:2007 03 2007 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,151 $64 Not Implemented
UA0001 # 04 Y:2007 04 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,147 $3,013 Not Implemented
UA0001 # 05 Y:2007 05 2007 UTILIZE JOB COSTING SOFTWARE $31,200 $8,489 Not Implemented
UA0001 # 06 Y:2007 06 2007 MINIMIZE WATER USAGE $564 $1,110 Not Implemented
UA0001 # 07 Y:2007 07 2007 RECOVER AND REUSE WASTE MATERIAL $6,000 $0 Not Implemented
OK0743 # 01 Y:2007 01 2007 RECOVER WASTE HEAT FROM EQUIPMENT $22,720 $5,010 Implemented
OK0743 # 02 Y:2007 02 2007 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,189 $569 Implemented
OK0743 # 03 Y:2007 03 2007 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $642 $6,000 Implemented
OK0743 # 04 Y:2007 04 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,598 $3,500 Implemented
OK0743 # 05 Y:2007 05 2007 INSTALL OCCUPANCY SENSORS $21,613 $2,450 Implemented
OK0743 # 06 Y:2007 06 2007 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $24,607 $0 Not Implemented
OK0743 # 07 Y:2007 07 2007 INSULATE BARE EQUIPMENT $5,413 $723 Implemented
WV0355 # 01 Y:2007 01 2007 USE RADIANT HEATER FOR SPOT HEATING $187,442 $70,000 Not Implemented