Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,333
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UL0245 # 03 Y:2000 | 03 | 2000 | USE CLEAN IN PLACE (CIP) SYSTEMS | $84 | $0 | Not Implemented |
UL0245 # 04 Y:2000 | 04 | 2000 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $3,000 | $0 | Not Implemented |
UM0165 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,237 | $9,748 | Implemented |
UM0165 # 02 Y:2000 | 02 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,860 | $0 | Implemented |
UM0165 # 03 Y:2000 | 03 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,996 | $1,750 | Implemented |
UM0165 # 04 Y:2000 | 04 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $13,852 | $13,583 | Not Implemented |
UM0165 # 05 Y:2000 | 05 | 2000 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $26,506 | $131,000 | Not Implemented |
UM0165 # 06 Y:2000 | 06 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $658 | $750 | Not Implemented |
UM0165 # 07 Y:2000 | 07 | 2000 | FILTER AND REUSE HYDRAULIC OIL | $37,145 | $10,500 | Not Implemented |
DS0168 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,922 | $5,987 | Not Implemented |
DS0168 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $1,741 | $2,484 | Not Implemented |
DS0168 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $22,182 | $53,350 | Not Implemented |
DS0168 # 04 Y:2000 | 04 | 2000 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $871 | $511 | Implemented |
DS0168 # 05 Y:2000 | 05 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $7,115 | $6,647 | Implemented |
DS0168 # 06 Y:2000 | 06 | 2000 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $5,027 | $18,608 | Not Implemented |
GT0692 # 01 Y:2000 | 01 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $7,357 | $2,000 | Implemented |
GT0692 # 02 Y:2000 | 02 | 2000 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $7,810 | $1,000 | Implemented |
GT0692 # 03 Y:2000 | 03 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $6,690 | $4,000 | Implemented |
GT0692 # 04 Y:2000 | 04 | 2000 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $3,465 | $500 | Not Implemented |
GT0692 # 05 Y:2000 | 05 | 2000 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $53,500 | $170,000 | Not Implemented |
GT0692 # 06 Y:2000 | 06 | 2000 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $9,831 | $26,400 | Not Implemented |
GT0692 # 07 Y:2000 | 07 | 2000 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $19,321 | $41,750 | Not Implemented |
GT0692 # 08 Y:2000 | 08 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $5,155 | $0 | Not Implemented |
IA0246 # 01 Y:2000 | 01 | 2000 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $19,500 | $22,000 | Not Implemented |
IA0246 # 02 Y:2000 | 02 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $18,200 | $10,275 | Not Implemented |